Your browser doesn't support javascript.
loading
Novel foetal echocardiographic image processing software (5D Heart) improves the display of key diagnostic elements in foetal echocardiography.
Hu, Wan-Yu; Zhou, Jin-Hong; Tao, Xiao-Ying; Li, Shi-Yan; Wang, Bei; Zhao, Bo-Wen.
Afiliação
  • Hu WY; Department of Diagnostic Ultrasound & Echocardiography, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, No. 3 East Qingchun Road, Hangzhou, 310016, People's Republic of China.
  • Zhou JH; Department of Ultrasonography, Quzhou People's Hospital, Quzhou, People's Republic of China.
  • Tao XY; Department of Ultrasonography, Jinhua Municipal Central Hospital, Jinhua, People's Republic of China.
  • Li SY; Department of Diagnostic Ultrasound & Echocardiography, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, No. 3 East Qingchun Road, Hangzhou, 310016, People's Republic of China.
  • Wang B; Department of Diagnostic Ultrasound & Echocardiography, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, No. 3 East Qingchun Road, Hangzhou, 310016, People's Republic of China.
  • Zhao BW; Department of Diagnostic Ultrasound & Echocardiography, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, No. 3 East Qingchun Road, Hangzhou, 310016, People's Republic of China. zbwcjp@zju.edu.cn.
BMC Med Imaging ; 20(1): 33, 2020 04 03.
Article em En | MEDLINE | ID: mdl-32245426
ABSTRACT

BACKGROUND:

To evaluate the clinical value of foetal intelligent navigation echocardiography (5D Heart) for the display of key diagnostic elements in basic sections.

METHODS:

3D volume datasets of 182 normal singleton foetuses were acquired with a four chamber view by using a volume probe. After processing the datasets by using 5D Heart, eight cardiac diagnostic planes were demonstrated, and the image qualities of the key diagnostic elements were graded by 3 doctors with different experiences in performing foetal echocardiography.

RESULTS:

A total of 231 volume datasets acquired from the 182 normal foetuses were used for 5D Heart analysis and display. The success rate of 8 standard diagnostic views was 88.2%, and the success rate of each diagnostic view was 55.8-99.2% and 70.7-99.0% for the random four chamber view as the initial section and for the apical four chamber view as the initial section, respectively. The success rate of each diagnostic element in the 8 diagnostic sections obtained by 5D Heart was 58.9%~ 100%. Excellent agreement was found between experienced sonographers and less-experienced sonographers (kappa> 0.769). Inter- and intra-observer agreement were substantial to near-perfect, kappa values ranging from 0.612 to 1.000 (Cohen's kappa).

CONCLUSIONS:

5D Heart can significantly improve the image quality of key diagnostic elements in foetal echocardiography with low operator dependency and good reproducibility.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Ecocardiografia / Coração Fetal Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Ecocardiografia / Coração Fetal Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Ano de publicação: 2020 Tipo de documento: Article