[Radiation dose and image quality of noncontrast chest CT in domestic and imported main stream manufacturers].
Wang, L; Yang, S J; Tan, Y Z; Luo, S; Kong, X; Tang, C X; Lu, M J; Qi, L; Zhou, C S; Lu, G M; Zhang, L J; Li, Y M.
Afiliação
  • Wang L; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Yang SJ; Department of Radiology, Tianjin Union Medical Center, Tianjin 300121, China.
  • Tan YZ; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Luo S; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Kong X; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Tang CX; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Lu MJ; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Qi L; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Zhou CS; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Lu GM; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Zhang LJ; Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, General Hospital of Eastern Theater Command, Nanjing 210002, China.
  • Li YM; Department of Radiology, Tianjin Union Medical Center, Tianjin 300121, China.
Zhonghua Yi Xue Za Zhi ; 100(15): 1148-1153, 2020 Apr 21.
Article em Zh | MEDLINE | ID: mdl-32311878
Objective: To compare the radiation dose and image quality of noncontrast chest CT and detection of ground-glass opacity pulmonary nodules (GGN) in domestic 128-slice spiral CT with the other CT scanners from three main stream manufacturers. Methods: From May 8, 2018 to October 31, 2018, noncontrast chest CT images from Neusoft 128-slice CT (75 males, 25 females, (42±16) years), dual-source 64-slice CT (53 males, 47 females, (50±16) years) and dual-source 128-slice CT scanners(69 males, 31 females, (62±17) years), Toshiba 128-slice CT (51 males, 49 females, (58±13) years) and GE 128-slice CT scanner (55 males, 45 females, (60±10) years) were collected in Eastern Theater Command and Tianjin People's Hospital. Radiation dose and image quality were evaluated.GGN detected both in Neusoft CT and dual-source CT scanners were used to analyze the displaying ability of lesions. Results: The noise in lung window of Neusoft CT ((37.8±4.9) HU) was higher than that of other mainstream CT scanners, and the noise in mediastinal window ((8.4±1.9) HU) was lower than that of GE 128-slice CT ((9.8±3.2) HU), but higher than that of dual-source CT and Toshiba 128-slice CT ((6.9±3.5)HU) (P<0.05). The absolute value of lung SNR in Neusoft CT was lower than that of other mainstream CT scanners, and the SNR in aorta (4.6±1.3) was lower than those of dual-source CT and Toshiba 128-slice CT(6.8±2.2) (P<0.05), but was not statistically significant compared with GE 128-slice CT (5.0±1.7). The mean CT value of upper lung ((-863±31) HU) at Neusoft CT was higher than 128-row dual-source CT ((-869±35) HU), and the mean CT value of aorta ((37±7) HU) was lower than that of Toshiba 128-slice CT((42±7) HU) and GE 128-slice CT ((45±9) HU) (P<0.05), while the mean CT values of the remaining lung and aorta were not statistically significant (P>0.05). The two readers had good to excellent consistency for image quality in five scanners (the highest kappa value=0.984). The delineation ability of Neusoft CT for GGN boundary was lower than that of dual-source CT (P<0.05), but had similar abilities to display the solid components, lobulation, burring, vacuoles, vascular bundle sign and pleural depression sign of GGN (all P>0.05). Radiation dose of Neusoft CT was lower than Toshiba 128-slice CT, but higher than dual-source 64-sliceCT and GE 128-slice CT scanners (P<0.05). Conclusions: With lower radiation dose than Toshiba 128-slice CT, Neusoft CT chest examination can meet the requirements of clinical diagnosis, but higher radiation dose and the lower image quality than dual-source CT and GE 128-slice CT shown in this study indicate further improvement is needed in terms of software and hardware.