Optical Biopsy: Automated Classification of Airway Endoscopic Findings Using a Convolutional Neural Network.
Dunham, Michael E; Kong, Keonho A; McWhorter, Andrew J; Adkins, Lacey K.
Afiliação
  • Dunham ME; Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Louisiana State University Health Sciences Center, New Orleans, Louisiana, U.S.A.
  • Kong KA; Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Louisiana State University Health Sciences Center, New Orleans, Louisiana, U.S.A.
  • McWhorter AJ; Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Louisiana State University Health Sciences Center, New Orleans, Louisiana, U.S.A.
  • Adkins LK; Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Louisiana State University Health Sciences Center, New Orleans, Louisiana, U.S.A.
Laryngoscope ; 132 Suppl 4: S1-S8, 2022 02.
Article em En | MEDLINE | ID: mdl-32343434
ABSTRACT
OBJECTIVES/

HYPOTHESIS:

Create an autonomous computational system to classify endoscopy findings. STUDY

DESIGN:

Computational analysis of vocal fold images at an academic, tertiary-care laryngology practice.

METHODS:

A series of normal and abnormal vocal fold images were obtained from the image database of an academic tertiary care laryngology practice. The benign images included normals, nodules, papilloma, polyps, and webs. A separate set of carcinoma and leukoplakia images comprised a single malignant-premalignant class. All images were classified with their existing labels. Images were randomly withheld from each class for testing. The remaining images were used to train and validate a neural network for classifying vocal fold lesions. Two classifiers were developed. A multiclass system classified the five categories of benign lesions. A separate analysis was performed using a binary classifier trained to distinguish malignant-premalignant from benign lesions.

RESULTS:

Precision ranged from 71.7% (polyps) to 89.7% (papilloma), and recall ranged from 70.0% (papilloma) to 88.0% (nodules) for the benign classifier. Overall accuracy for the benign classifier was 80.8%. The binary classifier correctly identified 92.0% of the malignant-premalignant lesions with an overall accuracy of 93.0%.

CONCLUSIONS:

Autonomous classification of endoscopic images with artificial intelligence technology is possible. Better network implementations and larger datasets will continue to improve classifier accuracy. A clinically useful optical cancer screening system may require a multimodality approach that incorporates nonvisual spectra. LEVEL OF EVIDENCE NA Laryngoscope, 132S1-S8, 2022.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Biópsia / Inteligência Artificial / Interpretação de Imagem Assistida por Computador / Doenças da Laringe / Redes Neurais de Computação / Laringoscopia Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Biópsia / Inteligência Artificial / Interpretação de Imagem Assistida por Computador / Doenças da Laringe / Redes Neurais de Computação / Laringoscopia Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article