Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis.
Shoman, Yara; Wild, Pascal; Hemmendinger, Maud; Graille, Melanie; Sauvain, Jean-Jacques; Hopf, Nancy B; Guseva Canu, Irina.
Afiliação
  • Shoman Y; Center for Primary Care and Public Health (Unisanté), University of Lausanne, 1066 Epalinges-Lausanne, Switzerland.
  • Wild P; Center for Primary Care and Public Health (Unisanté), University of Lausanne, 1066 Epalinges-Lausanne, Switzerland.
  • Hemmendinger M; Institut national de recherche et de sécurité (INRS), 54500 Vandœuvre-lès-Nancy, France.
  • Graille M; Center for Primary Care and Public Health (Unisanté), University of Lausanne, 1066 Epalinges-Lausanne, Switzerland.
  • Sauvain JJ; Center for Primary Care and Public Health (Unisanté), University of Lausanne, 1066 Epalinges-Lausanne, Switzerland.
  • Hopf NB; Center for Primary Care and Public Health (Unisanté), University of Lausanne, 1066 Epalinges-Lausanne, Switzerland.
  • Guseva Canu I; Center for Primary Care and Public Health (Unisanté), University of Lausanne, 1066 Epalinges-Lausanne, Switzerland.
Int J Mol Sci ; 21(11)2020 May 28.
Article em En | MEDLINE | ID: mdl-32481492
ABSTRACT
Isoprostanes are physiopathologic mediators of oxidative stress, resulting in lipid peroxidation. 8-isoprostane seems particularly useful for measuring oxidative stress damage. However, no reference range values are available for 8-isoprosante in exhaled breath condensate (EBC) of healthy adults, enabling its meaningful interpretation as a biomarker. We conducted this systematic review and meta-analysis according to the protocol following PROSPERO (CRD42020146623). After searching and analyzing the literature, we included 86 studies. After their qualitative synthesis and risk of bias assessment, 52 studies were included in meta-analysis. The latter focused on studies using immunological analytical methods and investigated how the concentrations of 8-isoprostane differ based on gender. We found that gender had no significant effect in 8-isoprostane concentration. Among other studied factors, such as individual characteristics and factors related to EBC collection, only the device used for EBC collection significantly affected measured 8-isoprostane concentrations. However, adjustment for the factors related to EBC collection, yielded uncertainty whether this effect is due to the device itself or to the other factors. Given this uncertainty, we estimated the reference range values of 8-isoprostane stratified by gender and EBC collection device. A better standardization of EBC collection seems necessary; as well more studies using chemical analytical methods to extend this investigation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Testes Respiratórios / Biomarcadores / Dinoprosta / Fatores Sexuais / Estresse Oxidativo Tipo de estudo: Diagnostic_studies / Qualitative_research / Systematic_reviews Limite: Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Testes Respiratórios / Biomarcadores / Dinoprosta / Fatores Sexuais / Estresse Oxidativo Tipo de estudo: Diagnostic_studies / Qualitative_research / Systematic_reviews Limite: Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article