A biomechanical confirmation of the relationship between critical shoulder angle (CSA) and articular joint loading.
Villatte, Guillaume; van der Kruk, Eline; Bhuta, Asim I; Zumstein, Matthias A; Moor, Beat K; Emery, Roger J H; Bull, Anthony M J; Reilly, Peter.
Afiliação
  • Villatte G; Department of Orthopaedic Surgery and Traumatology, Hôpital Gabriel Montpied, Clermont-Ferrand, France; Université Clermont Auvergne, SIGMA Clermont, Institut de Chimie de Clermont-Ferrand, Clermont-Ferrand, France; CNRS, UMR 6296, ICCF, Aubière, France. Electronic address: guivillatte@gmail.com.
  • van der Kruk E; Bioengineering Department, Imperial College, London, UK.
  • Bhuta AI; Bioengineering Department, Imperial College, London, UK.
  • Zumstein MA; Department of Orthopaedic Surgery and Traumatology, Inselspital, University of Bern, Bern, Switzerland.
  • Moor BK; Department of Orthopaedic Surgery and Traumatology, Inselspital, University of Bern, Bern, Switzerland.
  • Emery RJH; Division of Surgery, Imperial College, London, UK.
  • Bull AMJ; Department of Orthopaedic Surgery and Traumatology, Hôpital Gabriel Montpied, Clermont-Ferrand, France.
  • Reilly P; Department of Orthopaedic Surgery and Traumatology, Hôpital Gabriel Montpied, Clermont-Ferrand, France.
J Shoulder Elbow Surg ; 29(10): 1967-1973, 2020 Oct.
Article em En | MEDLINE | ID: mdl-32499200
ABSTRACT

BACKGROUND:

The critical shoulder angle (CSA) has been shown to be correlated with shoulder disease states. The biomechanical hypothesis to explain this correlation is that the CSA changes the shear and compressive forces on the shoulder. The objective of this study is to test this hypothesis by use of a validated computational shoulder model. Specifically, this study assesses the impact on glenohumeral biomechanics of modifying the CSA.

METHODS:

An inverse dynamics 3-dimensional musculoskeletal model of the shoulder was used to quantify muscle forces and glenohumeral joint forces. The CSA was changed by altering the attachment point of the middle deltoid into a normal CSA (33°), a reduced CSA of 28°, and an increased CSA of 38°. Subject-specific kinematics of slow and fast speed abduction in the scapular plane and slow and fast forward flexion measured by a 3-dimensional motion capture system were used to quantify joint reaction shear and compressive forces.

RESULTS:

Increasing the CSA results in increased superior-inferior forces (shearing forces; integrated over the range of motion; P < .05). Reducing CSA results in increased lateromedial (compressive) forces for both the maximum and integrated sum of the forces over the whole motion (P < .01). DISCUSSION/

CONCLUSION:

Changes in the CSA modify glenohumeral joint biomechanics with increasing CSA producing higher shear forces that could contribute to rotator cuff overuse, whereas reducing the CSA results in higher compressive forces that contribute to joint wear.