Your browser doesn't support javascript.
loading
Automated quantification of mitral valve tenting volume in functional mitral regurgitation by three-dimensional echocardiography.
Hübscher, Anne; Schwerg, Marius; Hoffmann, Saskia; Baldenhofer, Gerd; Heupel, Christian; Jasaityte, Ruta; Kruck, Sebastian; Stangl, Karl; Dreger, Henryk; Knebel, Fabian.
Afiliação
  • Hübscher A; Medizinische Klinik für Kardiologie und Angiologie, Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Schwerg M; Medizinische Klinik für Kardiologie und Angiologie, Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Hoffmann S; Medizinische Klinik für Kardiologie und Angiologie, Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Baldenhofer G; Medizinische Klinik für Kardiologie und Angiologie, Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Heupel C; DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany.
  • Jasaityte R; Medizinische Klinik für Kardiologie und Angiologie, Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Kruck S; Medizinische Klinik für Kardiologie und Angiologie, Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Stangl K; Cardio Centrum Ludwigsburg Bietigheim, Bietigheim-Bissingen, Germany.
  • Dreger H; Medizinische Klinik für Kardiologie und Angiologie, Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Knebel F; DZHK (German Centre for Cardiovascular Research), Partner Site, Berlin, Germany.
Echocardiography ; 37(7): 1043-1048, 2020 07.
Article em En | MEDLINE | ID: mdl-32530513
BACKGROUND: Tenting of the mitral leaflets is a major pathophysiological factor contributing to functional mitral regurgitation (FMR). A novel software tool allows automated quantification of the tenting volume (TnV) by 3D transesophageal echocardiography (TEE). The aims of this study are to investigate the correlations of biometric patient characteristics with the TnV and whether a threshold value for the diagnosis of a moderate or severe FMR can be calculated for the TnV. METHODS: This explorative and hypothesis-generating study analyzed the TnV of the mitral valve obtained by clinically indicated TEE. The mid-systolic, threefold calculated and averaged TnV from 80 patients with no or mild FMR and 27 patients with moderate or severe FMR was determined using the TomTec 4D MV Assessment tool. RESULTS: The TnV correlated significantly with the body size (r = 0.341), the weight (r = 0.272), and the body surface area (r = 0.320). After the adjustment to the body size, a threshold value of 1.25 cm3 /m was determined for the TnV by using a receiver-operating characteristic curve. This value distinguished moderate to severe from none to mild FMR with a sensitivity of 85% and a specificity of 71%. The intra-observer variability and inter-observer variability were determined to be 0.96 and 0.85, respectively. CONCLUSIONS: Automated assessment of TnV has the potential to support the diagnostic evaluation of FMR. Further studies are needed to validate this result, detect additional factors influencing the size of the TnV, and determine further thresholds for any degree of FMR.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ecocardiografia Tridimensional / Insuficiência da Valva Mitral Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ecocardiografia Tridimensional / Insuficiência da Valva Mitral Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article