Your browser doesn't support javascript.
loading
Transthoracic echocardiography monitoring during ASD closure using an artificial hand system.
Fu, Yun-Ching; Tsai, Shen Kou; Jian, Wen-Yen; Shyu, Tsung-Cheng; Chuang, Chieh-Mao; Hwang, Betau.
Afiliação
  • Fu YC; Pediatric Cardiology, Department of Pediatrics, Children's Hospital, China Medical University, No. 2, Yude Road, North District, Taichung, Taiwan, ROC.
  • Tsai SK; Cheng-Hsin General Hospital and National Taiwan University, No 45, Cheng Hsin St., Beitou, Taipei, Taiwan, ROC. no1sktsai@gmail.com.
  • Jian WY; Pediatric Cardiology, Heart Center, Cheng-Hsin General Hospital, No 45, Cheng Hsin St., Beitou, Taipei, Taiwan (ROC).
  • Shyu TC; Pediatric Cardiology, Department of Pediatrics, Children's Hospital, China Medical University, No. 2, Yude Road, North District, Taichung, Taiwan, ROC.
  • Chuang CM; Pediatric Cardiology, Department of Pediatrics, Children's Hospital, China Medical University, No. 2, Yude Road, North District, Taichung, Taiwan, ROC.
  • Hwang B; Pediatric Cardiology, Heart Center, Cheng-Hsin General Hospital, No 45, Cheng Hsin St., Beitou, Taipei, Taiwan (ROC).
Cardiovasc Ultrasound ; 18(1): 21, 2020 Jun 17.
Article em En | MEDLINE | ID: mdl-32552906
ABSTRACT

AIM:

Continuous real-time echocardiographic monitoring is essential for guidance during ASD closure. However, transthoracic echocardiography (TTE) can only be implemented intermittently during fluoroscopy. We evaluate a novel approach to provide real-time imaging during the entire procedure.

FINDING:

We developed a custom-made TTE monitoring apparatus using artificial hand (AH-TTE) that enables real-time TTE images during atrial septal defect (ASD) closure. Thirty-two patients underwent successful device implantation using AH-TTE monitoring without complications. The median duration for real-time AH-TTE monitoring was 22 min and the median fluoroscopy time was 7.2 min. One case of pericardial effusion and one of transient bradycardia event due to air embolism was detected. All patients had uneventful recoveries.

CONCLUSIONS:

Our simple and novel monitoring technique with AH-TTE provides TEE-like monitoring and may be a new alternative method for ASD closure. It gives real-time stable TTE images and minimizes radiation exposure for the interventional team during fluoroscopy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Inteligência Artificial / Ecocardiografia / Monitorização Intraoperatória / Ultrassonografia de Intervenção / Comunicação Interatrial Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Child / Child, preschool / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Inteligência Artificial / Ecocardiografia / Monitorização Intraoperatória / Ultrassonografia de Intervenção / Comunicação Interatrial Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Child / Child, preschool / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article