Your browser doesn't support javascript.
loading
Simulating Signal Aberration and Ranging Error for Ultrasonic Indoor Positioning.
Carotenuto, Riccardo; Merenda, Massimo; Iero, Demetrio; G Della Corte, Francesco.
Afiliação
  • Carotenuto R; DIIES Department, University Mediterranea of Reggio Calabria, 89126 Reggio Calabria, Italy.
  • Merenda M; DIIES Department, University Mediterranea of Reggio Calabria, 89126 Reggio Calabria, Italy.
  • Iero D; HWA srl, Spin-off University Mediterranea of Reggio Calabria, Via R. Campi II tr. 135, 89126 Reggio Calabria, Italy.
  • G Della Corte F; DIIES Department, University Mediterranea of Reggio Calabria, 89126 Reggio Calabria, Italy.
Sensors (Basel) ; 20(12)2020 Jun 23.
Article em En | MEDLINE | ID: mdl-32585908
ABSTRACT
Increasing efforts toward the development of positioning techniques testify the growing interest for indoor position-based applications and services. Many applications require accurate indoor positioning or tracking of people and assets, and some market sectors are starting a rapid growth of products based on these technologies. Ultrasonic systems have already been demonstrating their effectiveness and to possess the desired positioning accuracy and refresh rates. In this work, it is shown that a typical signal used in ultrasonic positioning systems to estimate the range between the target and reference points-namely, the linear chirp-due to the effects of acoustic diffraction, in some cases, undergoes a shape aberration, depending on the shape and size of the transducer and on the angle under which the transducer is seen by the receiver. In the presence of such signal shape aberrations, even one of the most robust ranging techniques, which is based on cross-correlation, provides results affected by a much greater error than expected. Numerical simulations are carried out for a typical ultrasonic chirp, ultrasonic emitter, and range technique based on cross-correlation and for a typical office room, obtained using the academic acoustic simulation software Field II. Spatial distributions of the ranging error are provided, clearly showing the favorable low error regions. The work demonstrates that particular attention must be paid to the design of the acoustic section of the ultrasonic positioning systems, considering both the shape and size of the ultrasonic emitters and the shape of the acoustic signal used.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article