Your browser doesn't support javascript.
loading
"Clinical comparison of bond failure rate between two types of mandibular canine-canine bonded orthodontic retainers- a randomized clinical trial".
Nagani, Nasreen Iqbal; Ahmed, Imtiaz; Tanveer, Faiqa; Khursheed, Hafiza Marium; Farooqui, Waqas Ahmed.
Afiliação
  • Nagani NI; Department Of Orthodontics, Dr. Ishrat-Ul-Ebad Khan Institute Of Oral Health Sciences (DIKIOHS), Dow University Of Health Sciences, Karachi, Pakistan. nasreen.iqbal@duhs.edu.pk.
  • Ahmed I; Present Address: Adam Plaza, flat no 103, opp: New Town Masjid, Gurumandir, Karachi, Pakistan. nasreen.iqbal@duhs.edu.pk.
  • Tanveer F; Department Of Orthodontics, Dr. Ishrat-Ul-Ebad Khan Institute Of Oral Health Sciences (DIKIOHS), Dow University Of Health Sciences, Karachi, Pakistan.
  • Khursheed HM; Department Of Orthodontics, Dr. Ishrat-Ul-Ebad Khan Institute Of Oral Health Sciences (DIKIOHS), Dow University Of Health Sciences, Karachi, Pakistan.
  • Farooqui WA; Department Of Orthodontics, Dr. Ishrat-Ul-Ebad Khan Institute Of Oral Health Sciences (DIKIOHS), Dow University Of Health Sciences, Karachi, Pakistan.
BMC Oral Health ; 20(1): 180, 2020 06 29.
Article em En | MEDLINE | ID: mdl-32600325
ABSTRACT

BACKGROUND:

Bonded retainers are widely used as they are esthetically pleasing, easily acceptable, provide greater stability, compliance free and causes no soft tissue irritation and speech problems. Though, fracture and bond failure are their shortcomings. Therefore, the objectives of this study were to evaluate the number of bond failures and type of failure pattern between two types of mandibular canine-canine bonded retainers.

METHODS:

Total 60 subjects were recruited initially and were assessed for eligibility, out of which 6 were excluded and 2 were lost to follow up. They were randomly divided into two groups. Fiber reinforced composite (FRC) retainers were inserted in group 1 subjects while group 2 subjects received multistranded stainless steel (MSW) retainers. The subjects were recalled after every 3 months over a period of 1 year. Bond failure rate and failure pattern based on adhesive remnant index were evaluated at each visit. The bond failure rate and failure pattern were compared between the two retainers by using Chi-square test.

RESULTS:

The bond failure rates were 42.94% for FRC retainer and 31.41% for MSW retainer. Hence, total number of bond failures in both retainers were 37.17%. The difference of bond failure between two groups was statistically significant (p = 0.012). Type "0" failure pattern was detected commonly with both types of retainers (p <  0.001).

CONCLUSION:

Our findings indicate that multistranded stainless steel wire retainer is a superior option to be used for fixed lingual retention in mandibular arch as it exhibited lower bond failure as compared to fiber reinforced composite retainer. Adhesive failure is the most common type of bond failure observed with both types of fixed retainers. TRIAL REGISTRATION ID NCT03881813 ( https//clinicaltrials.gov/ ); March 19, 2019, retrospective registration.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colagem Dentária / Desenho de Aparelho Ortodôntico / Contenções Ortodônticas / Materiais Dentários Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colagem Dentária / Desenho de Aparelho Ortodôntico / Contenções Ortodônticas / Materiais Dentários Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article