Your browser doesn't support javascript.
loading
Outcomes of stapler repair with anastomosis for stoma prolapse.
Koide, Yoshikazu; Maeda, Kotaro; Katsuno, Hidetoshi; Hanai, Tsunekazu; Masumori, Koji; Matsuoka, Hiroshi; Endo, Tomoyoshi; Cheong, Yeong Cheol; Uyama, Ichiro.
Afiliação
  • Koide Y; Department of Surgery, Fujita Health University School of Medicine, Toyoake, Japan.
  • Maeda K; International Medical Center Fujita, Health University Hospital, 1-98, Kutsukake, Toyoake, 470-1192, Japan. kmaeda@fujita-hu.ac.jp.
  • Katsuno H; Department of Surgery, Fujita Health University Okazaki Medical Center, Okazaki, Japan.
  • Hanai T; Department of Surgery, Fujita Health University School of Medicine, Toyoake, Japan.
  • Masumori K; Department of Surgery, Fujita Health University School of Medicine, Toyoake, Japan.
  • Matsuoka H; Department of Surgery, Fujita Health University School of Medicine, Toyoake, Japan.
  • Endo T; Department of Surgery, Fujita Health University Okazaki Medical Center, Okazaki, Japan.
  • Cheong YC; Department of Surgery, Fujita Health University School of Medicine, Toyoake, Japan.
  • Uyama I; Department of Surgery, Fujita Health University School of Medicine, Toyoake, Japan.
Surg Today ; 51(2): 226-231, 2021 Feb.
Article em En | MEDLINE | ID: mdl-32656699
PURPOSE: The published data on the outcomes of an operative repair for stoma prolapse are limited. This study aimed to clarify the long-term outcomes of stapler repair with anastomosis for stoma prolapse. METHODS: Twenty-four patients (15 men, median age 64 years, range 33-88 years) undergoing 25 stapler repairs with anastomosis were prospectively registered, and their medical records were retrospectively reviewed. RESULTS: The median length of prolapse was 10 cm (range 5-22). Stoma prolapse repair was performed by means of 16 loop colostomies, four end colostomies, three loop ileostomies, and one end ileostomy. A stapler was used 4.6 times on average (range 4-8). The average operative time and bleeding were 40.8 (range 15-75) min and 40 (range 0-214) mL, respectively. No mortality and morbidity were observed after surgery. A recurrence of stoma prolapse was reported in only one of 25 repairs (4%) at the proximal limb of loop ileostomy during a median follow-up period of 1 year (range 1-120 months). However, a new stoma prolapsed in one untreated limb of loop stoma. CONCLUSIONS: Stapler repair with anastomosis is a safe and minimally invasive treatment option for stoma prolapse with a low recurrence. However, the effectiveness of reparing stoma prolapse on the proximal limb of loop ileostomy might be limited.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Grampeadores Cirúrgicos / Anastomose Cirúrgica / Colostomia / Ileostomia / Procedimentos Cirúrgicos Minimamente Invasivos / Estomas Cirúrgicos Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Grampeadores Cirúrgicos / Anastomose Cirúrgica / Colostomia / Ileostomia / Procedimentos Cirúrgicos Minimamente Invasivos / Estomas Cirúrgicos Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article