Your browser doesn't support javascript.
loading
Weak polyelectrolyte brushes: re-entrant swelling and self-organization.
Senechal, Vincent; Saadaoui, Hassan; Vargas-Alfredo, Nelson; Rodriguez-Hernandez, Juan; Drummond, Carlos.
Afiliação
  • Senechal V; CNRS, Centre de Recherche Paul Pascal (CRPP), UMR 5031, F-33600 Pessac, France. carlos.drummond@crpp.cnrs.fr and Université de Bordeaux, Centre de Recherche Paul Pascal, F-33600 Pessac, France.
  • Saadaoui H; CNRS, Centre de Recherche Paul Pascal (CRPP), UMR 5031, F-33600 Pessac, France. carlos.drummond@crpp.cnrs.fr and Université de Bordeaux, Centre de Recherche Paul Pascal, F-33600 Pessac, France.
  • Vargas-Alfredo N; Instituto de Ciencia y Tecnología de Polímeros, CSIC, Juan de la Cierva 3, 28006, Madrid, Spain.
  • Rodriguez-Hernandez J; Instituto de Ciencia y Tecnología de Polímeros, CSIC, Juan de la Cierva 3, 28006, Madrid, Spain.
  • Drummond C; CNRS, Centre de Recherche Paul Pascal (CRPP), UMR 5031, F-33600 Pessac, France. carlos.drummond@crpp.cnrs.fr and Université de Bordeaux, Centre de Recherche Paul Pascal, F-33600 Pessac, France.
Soft Matter ; 16(33): 7727-7738, 2020 Aug 26.
Article em En | MEDLINE | ID: mdl-32735003
ABSTRACT
We have studied the combined influence of pH and ionic strength on the properties of brushes of a weak polyion, poly(acrylic acid), in conditions of grafting density close to the mushroom-brush crossover. By combining atomic force microscopy AFM and quartz crystal microbalance, we show that at low ionic strengths the conformational change of grafted polyions is non-monotonic with increasing pH due to the counterintuitive variation of the ionization degree. Thus, reentrant swelling of the polymer chains is observed with increasing pH. This effect is more important at low polymer grafting densities, when it is accompanied by in-plane heterogeneous distribution at intermediate pH values. In addition, we observed self-assembly on the polymer brush (formation of holes and islands) at pH values below pKa, due to the short-range attractive interaction between uncharged grafted chains. The sensitivity of the ionization of grafted chains to the physicochemical environment was also studied by measuring the interaction force between a silica tip and polymer brushes by atomic force microscopy. The dependence of the ionization of polyions on the presence of the tip points toward important charge regulation effects, in particular at pH values corresponding to partial ionization of the polyion.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article