Your browser doesn't support javascript.
loading
Vaginal cuff perforation during robotic-assisted mesh recto-sacrocolpopexy.
Chavez, Jacqueline; Finsterbusch, Carlos; Olson, Craig; Zimmern, Philippe E.
Afiliação
  • Chavez J; UT Southwestern Medical Center Dallas Texas USA.
  • Finsterbusch C; UT Southwestern Medical Center Dallas Texas USA.
  • Olson C; UT Southwestern Medical Center Dallas Texas USA.
  • Zimmern PE; UT Southwestern Medical Center Dallas Texas USA.
IJU Case Rep ; 3(3): 83-85, 2020 May.
Article em En | MEDLINE | ID: mdl-32743477
ABSTRACT

INTRODUCTION:

We report on the management of intraoperative vaginal cuff perforation during robotic-assisted mesh recto-sacrocolpopexy for vaginal vault prolapse with defecatory dysfunction. CASE PRESENTATION A 75-year-old woman with vaginal bulge and constipation was to undergo a joint robotic mesh recto-sacrocolpopexy. Intraoperatively, mesh was secured to the left posterior vaginal wall following dissection. Prior to contralateral suture placement, the vaginal cuff split open and exposed an end-to-end anastomotic sizer previously inserted in the vagina. Due to subsequent mesh erosion risk, we proceeded with vaginotomy closure with running and interrupted absorbable sutures, removal of mesh, direct suture rectopexy to the promontory, and enterocele defect correction by reapproximating the right and left wings of the peritoneum flaps over the rectum with running sutures. Patient reported satisfactory outcomes after 2 years.

CONCLUSION:

We reviewed our experience with vaginal cuff perforation during robotic-assisted mesh recto-sacrocolpopexy prompting enterocele repair and rectopexy without mesh.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article