Your browser doesn't support javascript.
loading
Arthroscopic Bankart repair with all-suture anchors does not cause important glenoid bone osteolysis: a volumetric CT study of 143 anchors.
Ruiz Ibán, Miguel Angel; Vega Rodriguez, Rosa; Díaz Heredia, Jorge; Pérez Expósito, Roque; Zarcos Paredes, Irene; Ruiz Díaz, Raquel.
Afiliação
  • Ruiz Ibán MA; Investigation Performed at Unidad de Hombro y Codo, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain. drmri@hotmail.com.
  • Vega Rodriguez R; Investigation Performed at Unidad de Hombro y Codo, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain.
  • Díaz Heredia J; Investigation Performed at Unidad de Hombro y Codo, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain.
  • Pérez Expósito R; Investigation Performed at Unidad de Hombro y Codo, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain.
  • Zarcos Paredes I; Investigation Performed at Unidad de Hombro y Codo, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain.
  • Ruiz Díaz R; Investigation Performed at Unidad de Hombro y Codo, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2152-2158, 2021 Jul.
Article em En | MEDLINE | ID: mdl-32754864
ABSTRACT

PURPOSE:

To evaluate with computed tomography (CT) the incidence of anchor-related osteolysis after implantation of two types of all-suture anchors for the management of labral lesions in shoulder instability.

METHODS:

Single-cohort, observational study with 12-month follow-up. Thirty-three participants (27 males/6 females; age 38.3 years [SD 11.3]) with anterior labral lesions in which 143 all-suture anchors (71 Iconix 1.4 mm and 72 Suturefix 1.7 mm) were implanted were evaluated with a CT performed a mean of 15.4 [3.85] months after surgery. The volume of the bone defects was measured in the CT. Every anchor was classified into one of four groups (1) no bone defect. (2) Partial bone defect (defects smaller than the drill used for anchor placement). (3) Tunnel enlargement (defects larger than the drill volume but smaller than twice that volume). (4) Cystic lesion (defects larger than twice the drill volume).

RESULTS:

No bone defect was identified in 16 anchors (11.2%, [95% CI 6.5-17.5%]). A partial bone defect was found in 84 anchors (58.7% [50.2-66.9%]). Tunnel enlargement was found in 43 anchors (30.11% [22.6-37.6%]). No anchor caused cystic lesions (0% [0-2.5%]). The defect volume was a mean of 27.8 mm3 (SD 18.4 mm3, minimum 0 mm3, maximum 94 mm3). Neither the position in the glenoid nor the type of implant used had a significant effect in the type or size of the defects.

CONCLUSION:

When using all-suture anchors in the glenoid during instability surgery, relevant bone osteolytic defects are rare at 1-year follow-up. Most anchor insertion tunnels will fill completely (11%) or partially (59%) with bone. Tunnel enlargement will develop in 30% of anchors. No cystic defects larger than 0.125 cm3 were observed. There is a low risk that all-suture anchors cause significant osteolytic bone defects in the glenoid. These implants can be used safely. Level of evidence IV.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Osteólise / Artroplastia / Artroscopia / Articulação do Ombro / Âncoras de Sutura / Instabilidade Articular Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Osteólise / Artroplastia / Artroscopia / Articulação do Ombro / Âncoras de Sutura / Instabilidade Articular Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article