Your browser doesn't support javascript.
loading
Comparison of Outcomes of Percutaneous Arteriovenous Fistulae Creation by Ellipsys and WavelinQ Devices.
Shahverdyan, Robert; Beathard, Gerald; Mushtaq, Nasir; Litchfield, Terry F; Nelson, Peter R; Jennings, William C.
Afiliação
  • Shahverdyan R; Vascular Access Center, Asklepios Clinic Barmbek, Hamburg, Germany. Electronic address: robert.shahverdyan@icloud.com.
  • Beathard G; Department of Internal Medicine, Division of Nephrology, University of Texas Medical Branch, Galveston, Texas.
  • Mushtaq N; Department of Biostatistics and Epidemiology, University of Oklahoma Health Sciences Center, Tulsa, Oklahoma.
  • Litchfield TF; Access Solutions, Blanchardville, Wisconsin.
  • Nelson PR; School of Community Medicine, University of Oklahoma, Tulsa, Oklahoma.
  • Jennings WC; Department of Vascular Surgery, University of Oklahoma, Tulsa, Oklahoma.
J Vasc Interv Radiol ; 31(9): 1365-1372, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32792280
PURPOSE: The purpose of this study was to compare the clinical outcomes of Ellipsys with those of WavelinQ-4F percutaneous arteriovenous fistulae (pAVF) devices in a single center by a single operator. MATERIALS AND METHODS: A retrospective review was conducted in 100 patients who underwent pAVFs procedures (65 Ellipsys and 35 WavelinQ patients) and created between December 2017 and December 2019. A total of 69% were male and 37% were diabetic. Median age was 64.1 years (range: 28-86), and median body mass index was 27.2 (range: 15-45.1) kg/m2. A procedure sequence algorithm was followed for selecting all vascular accesses created. RESULTS: Ellipsys outcomes were compared to WavelinQ outcomes. Technical success was 100% versus 97%, respectively, and median procedure times were 14 versus 63 minutes, respectively (P < .001), with 183 (1-487) versus 185 (0-760) days follow-up, respectively. Maturation at 4 weeks was 68.3% versus 54.3%, respectively, and median times to cannulation were 60 (1-164) versus 90 (1-180) days, respectively. Successful pAVF dialysis was established in 31 of 39 patients (79.5%) versus 14 of 24 patients (58%), respectively (P = .071), dialysis patients with access-related adverse events observed in 4 individuals (1 Ellipsys versus 3 WavelinQ). Six patients (5 versus 1) with matured outflow from previous AVFs underwent first-day cannulations. Interventions were performed in 27.7% (33 Ellipsys) and 26.5% (15 WavelinQ) patients, and the number of interventions per patient-years was 0.96 versus 0.46, respectively. pAVF failure was seen in 15.4% versus 37.1% patients, respectively (P = .0137). Secondary patency at 12 months was significantly higher among patients who had an Ellipsys procedure (82%) than among those who underwent the WavelinQ procedure (60%). CONCLUSIONS: pAVFs were created with high technical success and low complications with both devices. Ellipsys pAVFs demonstrated significantly shorter procedure times without a need for radiation exposure and with superior secondary patency.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Derivação Arteriovenosa Cirúrgica / Procedimentos Endovasculares / Antebraço Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Derivação Arteriovenosa Cirúrgica / Procedimentos Endovasculares / Antebraço Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article