Your browser doesn't support javascript.
loading
Identification of Cell Status via Simultaneous Multitarget Imaging Using Programmable Scanning Electrochemical Microscopy.
Ning, Xin; Wu, Tao; Xiong, Qiang; Zhang, Fan; He, Pin-Gang.
Afiliação
  • Ning X; School of Chemistry and Molecular Engineering, East China Normal University, No. 500 Dongchuan Road, Shanghai 200241, P. R. China.
  • Wu T; School of Chemistry and Molecular Engineering, East China Normal University, No. 500 Dongchuan Road, Shanghai 200241, P. R. China.
  • Xiong Q; School of Chemistry and Molecular Engineering, East China Normal University, No. 500 Dongchuan Road, Shanghai 200241, P. R. China.
  • Zhang F; School of Chemistry and Molecular Engineering, East China Normal University, No. 500 Dongchuan Road, Shanghai 200241, P. R. China.
  • He PG; School of Chemistry and Molecular Engineering, East China Normal University, No. 500 Dongchuan Road, Shanghai 200241, P. R. China.
Anal Chem ; 92(18): 12111-12115, 2020 09 15.
Article em En | MEDLINE | ID: mdl-32799521
ABSTRACT
A programmable multitarget-response electrochemical imaging technique was presented using scanning electrochemical microscopy (SECM) combined with a self-designed waveform. The potential waveform applied to the tip decreased the charging current caused by the potential switch, enhancing the signal-to-noise ratio. This programmable SECM (P-SECM) method was used to scan a metal strip for verifying its feasibility in feedback mode. Since it could achieve simultaneous multitarget imaging during one single imaging process, PC12 cells status was imaged and identified through three different molecules (FcMeOH, Ru(NH3)63+, and oxygen). The FcMeOH image eliminated the error from cell height, and the Ru(NH3)63+ image verified the change of membrane permeability. Moreover, the oxygen image demonstrated the bioactivity of the cell via its intensity of respiration. Combining information from these three molecules, the cell status could be determined accurately and also the error caused by time consumption with multiple scans in traditional SECM was eliminated.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Compostos Ferrosos / Compostos de Rutênio / Microscopia Eletroquímica de Varredura Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Compostos Ferrosos / Compostos de Rutênio / Microscopia Eletroquímica de Varredura Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article