Your browser doesn't support javascript.
loading
Simple and rapid detection of free 3-monochloropropane-1,2-diol based on cysteine modified silver nanoparticles.
Martin, Aka Alla; Fodjo, Essy Kouadio; Marc, Gouli Bi Irié; Albert, Trokourey; Kong, Cong.
Afiliação
  • Martin AA; Key Laboratory of East China Sea Fishery Resources Exploitation, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, China; Physical Chemistry Laboratory, UFR SSMT, Université Felix Houphouet Boigny, 22 BP 582
  • Fodjo EK; Physical Chemistry Laboratory, UFR SSMT, Université Felix Houphouet Boigny, 22 BP 582 Abidjan 22, Cote d'Ivoire. Electronic address: kouadio.essy@univ-fhb.edu.ci.
  • Marc GBI; Physical Chemistry Laboratory, UFR SSMT, Université Felix Houphouet Boigny, 22 BP 582 Abidjan 22, Cote d'Ivoire.
  • Albert T; Physical Chemistry Laboratory, UFR SSMT, Université Felix Houphouet Boigny, 22 BP 582 Abidjan 22, Cote d'Ivoire.
  • Kong C; Key Laboratory of East China Sea Fishery Resources Exploitation, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, China; Shanghai Key Laboratory of Forensic Medicine (Academy of Forensic Science), Shanghai 2
Food Chem ; 338: 127787, 2021 Feb 15.
Article em En | MEDLINE | ID: mdl-32827901
A rapid colorimetric method using cysteine-modified silver nanoparticles (Cys-AgNPs) is applied for the detection of 3-monochloropropane-1,2-diol (3-MCPD). Indeed, in the presence of 3-MCPD, the color of Cys-AgNPs solution changes from yellow to pink within five minutes at 100 °C and pH 9.3. This change is mainly attributed to the ability of amino group of cysteine to react with 3-MCPD to form N-(2,3-dihydroxypropyl)-amino acid grafted on AgNPs (3-MCPD-Cys-AgNPs) in alkaline medium. This color change makes 3-MCPD to be clearly detectable by unassisted visual means even at 0.1 µg⋅mL-1. Besides, using UV-Vis spectroscopic technique, a linear range from 0.1 µg⋅mL-1 to 1.25 µg⋅mL-1 for 3-MCPD detection is obtained, with a calculated detection limit of 0.084 µg⋅mL-1. These results suggest that this sensing technique is sensitive to 3-MCPD and may have a substantial application in the rapid detection of food contaminants particularly, where quality and safety of food products are paramount concern.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prata / Cisteína / Alfa-Cloridrina / Nanopartículas Metálicas / Análise de Alimentos Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prata / Cisteína / Alfa-Cloridrina / Nanopartículas Metálicas / Análise de Alimentos Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article