Your browser doesn't support javascript.
loading
Constant-wavelength synchronous fluorescence spectrometry for simultaneous and rapid determination of five polycyclic aromatic hydrocarbon residues in dairy products.
Cai, Qihong; Zhao, Chengfei; Zhu, Hang; Shen, Yiping; Hou, Huiqing; Tang, Yaoji.
Afiliação
  • Cai Q; Pharmaceutical and Medical Technology College of Putian University, Putian, Fujian, China.
  • Zhao C; Key Laboratory of Pharmaceutical Analysis and Laboratory Medicine (Putian University), Fujian Province University, Putian, Fujian, China.
  • Zhu H; Pharmaceutical and Medical Technology College of Putian University, Putian, Fujian, China.
  • Shen Y; Key Laboratory of Pharmaceutical Analysis and Laboratory Medicine (Putian University), Fujian Province University, Putian, Fujian, China.
  • Hou H; Pharmaceutical and Medical Technology College of Putian University, Putian, Fujian, China.
  • Tang Y; Key Laboratory of Pharmaceutical Analysis and Laboratory Medicine (Putian University), Fujian Province University, Putian, Fujian, China.
Luminescence ; 36(2): 353-359, 2021 Mar.
Article em En | MEDLINE | ID: mdl-32959966
ABSTRACT
A new method for simultaneously determining five polycyclic aromatic hydrocarbons (PAHs) (fluorene, benzofluorene, pyrene, benzo(a)pyrene, and perylene) in dairy products using constant-wavelength synchronous fluorescence spectrometry (CWSFS) was established in this study. Acetonitrile was chosen as the extraction solvent to extract the five PAHs from the dairy products, and an ultrasound extraction method was adopted. The supernatants were filtered using a 0.45-µm microporous filter membrane and concentrated to dryness with a nitrogen dryer. The extracts were then re-dissolved in cyclohexane for analysis. To overcome interference from the background matrix and between PAHs, the difference in wavelength (Δλ) at 40 nm was chosen for CWSFS scanning. With only one single scan, the five PAHs in dairy products could be distinguished and determined using the standard curve method without the need for previous chromatographic separation of the analyte solution. Detection limits of fluorene, benzofluorene, pyrene, benzo(a)pyrene, and perylene were 0.0051 µg·L-1 , 0.016 µg·L-1 , 0.021 µg·L-1 , 0.0056 µg·L-1 , and 0.0062 µg·L-1 , respectively. Recoveries were between 85.60% and 98.42%. These five PAHs in dairy products were determined with good results and therefore expected to be a routine detection method for PAHs in dairy products.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Perileno / Hidrocarbonetos Policíclicos Aromáticos Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Perileno / Hidrocarbonetos Policíclicos Aromáticos Idioma: En Ano de publicação: 2021 Tipo de documento: Article