Your browser doesn't support javascript.
loading
Effect of Fundus Fluorescein Angiography on Semiautomated Aqueous Flare Measurements.
Halim, Muhammad Sohail; Onghanseng, Neil; Park, Jung Hyun; Yilmaz, Mervenur; Segawa, Asadu; Ertop, Mestan; Hassan, Muhammad; Tran, Anh Nt; Aktas, Zeynep; Ozdek, Sengul; Gurelik, Gokhan; Do, Diana V; Sepah, Yasir J; Nguyen, Quan Dong; Hasanreisoglu, Murat.
Afiliação
  • Halim MS; Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, California, USA.
  • Onghanseng N; Ocular Imaging Research and Reading Center, Sunnyvale, California, USA.
  • Park JH; Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, California, USA.
  • Yilmaz M; Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, California, USA.
  • Segawa A; Department of Ophthalmology, Gazi University, School of Medicine, Ankara, Turkey.
  • Ertop M; Department of Ophthalmology, Gazi University, School of Medicine, Ankara, Turkey.
  • Hassan M; Department of Ophthalmology, Gazi University, School of Medicine, Ankara, Turkey.
  • Tran AN; Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, California, USA.
  • Aktas Z; Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, California, USA.
  • Ozdek S; Department of Ophthalmology, Gazi University, School of Medicine, Ankara, Turkey.
  • Gurelik G; Department of Ophthalmology, Gazi University, School of Medicine, Ankara, Turkey.
  • Do DV; Department of Ophthalmology, Gazi University, School of Medicine, Ankara, Turkey.
  • Sepah YJ; Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, California, USA.
  • Nguyen QD; Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, California, USA.
  • Hasanreisoglu M; Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, California, USA.
Ocul Immunol Inflamm ; 30(2): 424-427, 2022 Feb 17.
Article em En | MEDLINE | ID: mdl-32966150
ABSTRACT

PURPOSE:

To evaluate the effects of fluorescein fundus angiography (FFA) on semiautomated aqueous flare measurements.

METHODS:

Laser flare photometer (LFP) measurements was performed at baseline, 30 min, and 4 h after the intravenous administration of sodium fluorescein dye. FFA was performed immediately after the baseline LFP measurement. LFP values at 30 min and 4 h after FFA were compared to baseline values. Mean change in LFP measurements at 30 min and 4 hafter baseline was compared between FFA arm and controls.

RESULTS:

The mean flare measurement in the FFA and control arm dropped 6% (p value = 0.002) and 9% (p value = 0.04), respectively. Mean change in LFP measurement at 30 min and 4 h after baseline was not significant between FFA arm and controls.

CONCLUSIONS:

Administration of fluorescein dye does not increase LFP values. The decrease in the LFP measurement following FFA may be attributed to dilation drops.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Humor Aquoso / Uveíte Anterior Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Humor Aquoso / Uveíte Anterior Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article