Your browser doesn't support javascript.
loading
CT Angiography of the Heart and Aorta in TIA and Ischaemic Stroke: Cardioembolic Risk Sources and Clinical Implications.
Holswilder, Ghislaine; Wermer, Marieke Jh; Holman, Eduard R; Kruyt, Nyika D; Kroft, Lucia Jm; van Walderveen, Marianne Aa.
Afiliação
  • Holswilder G; Department of Radiology, Leiden University Medical Center, Albinusdreef 2, PO Box 9600, 2300 RC, Leiden, the Netherlands. Electronic address: G.Holswilder@lumc.nl.
  • Wermer MJ; Department of Neurology, Leiden University Medical Center Albinusdreef 2, PO Box 9600, 2300 RC, Leiden, the Netherlands.
  • Holman ER; Department of Cardiology, Leiden University Medical Center Albinusdreef 2, PO Box 9600, 2300 RC, Leiden, the Netherlands.
  • Kruyt ND; Department of Neurology, Leiden University Medical Center Albinusdreef 2, PO Box 9600, 2300 RC, Leiden, the Netherlands.
  • Kroft LJ; Department of Radiology, Leiden University Medical Center, Albinusdreef 2, PO Box 9600, 2300 RC, Leiden, the Netherlands.
  • van Walderveen MA; Department of Radiology, Leiden University Medical Center, Albinusdreef 2, PO Box 9600, 2300 RC, Leiden, the Netherlands.
J Stroke Cerebrovasc Dis ; 29(12): 105326, 2020 Dec.
Article em En | MEDLINE | ID: mdl-33010723
ABSTRACT

BACKGROUND:

Cardiac emboli are important causes of (recurrent) ischaemic stroke. Aorta atherosclerosis might also be associated with an increased risk of stroke recurrence. This study aimed to evaluate the yield and clinical implications of CT-angiography (CTA) of the heart and aorta in the diagnostic workup of transient ischaemic attack (TIA) or ischaemic stroke.

METHODS:

CTA of the heart and aortic arch was performed in TIA/ischaemic stroke patients, in addition to routine diagnostic workup. Occurrence of cardioembolic (CE) risk sources and complex aortic plaques were assessed. Implications of cardiac CTA for therapeutic management were evaluated

RESULTS:

Sixty-seven patients were included (TIA n = 33, ischaemic stroke n = 34) with a mean age of 68 years (range 51-89) and median NIHSS of 0 (interquartile range 0-2). CE risk sources were detected in 29 (43%) patients. An intracardiac thrombus was present in 2 patients (3%; TIA 0%; ischaemic stroke 6%). Medium/low-risk CE sources included mitral annular calcification (9%), aortic valve calcification (18%) and patent foramen ovale (18%). Complex aortic plaque was identified in 16 patients (24%). In two patients with an intracardiac thrombus, therapeutic management changed from antiplatelet to oral anticoagulation.

CONCLUSIONS:

CTA of the heart and aorta has a high yield for detection of embolic risk sources in TIA/ischaemic stroke, with clinical consequences for 6% of ischaemic stroke patients. Implementation of CTA of the heart and aorta in the acute stroke setting seems valuable, but cost-effectiveness of this approach remains to be determined.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças da Aorta / Aortografia / Ataque Isquêmico Transitório / Acidente Vascular Cerebral / Embolia / Tomografia Computadorizada Multidetectores / Angiografia por Tomografia Computadorizada / Cardiopatias Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças da Aorta / Aortografia / Ataque Isquêmico Transitório / Acidente Vascular Cerebral / Embolia / Tomografia Computadorizada Multidetectores / Angiografia por Tomografia Computadorizada / Cardiopatias Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article