Your browser doesn't support javascript.
loading
Inter-donor variability in deformability of red blood cells in blood units.
Barshtein, Gregory; Rasmusen, Tanja L; Zelig, Orly; Arbell, Dan; Yedgar, Saul.
Afiliação
  • Barshtein G; Department of Biochemistry, Faculty of Medicine, Hebrew University, Jerusalem, Israel.
  • Rasmusen TL; Department of Biochemistry, Faculty of Medicine, Hebrew University, Jerusalem, Israel.
  • Zelig O; Blood Bank, Hadassah-Hebrew University Hospital, Jerusalem, Israel.
  • Arbell D; Department of Pediatric Surgery, Hadassah-Hebrew University Hospital, Jerusalem, Israel.
  • Yedgar S; Department of Biochemistry, Faculty of Medicine, Hebrew University, Jerusalem, Israel.
Transfus Med ; 30(6): 492-496, 2020 Dec.
Article em En | MEDLINE | ID: mdl-33015934
ABSTRACT

OBJECTIVE:

This study aimed to examine the donor-to-donor variability in the deformability of red blood cells (RBCs) from freshly collected blood donations (F-RBC) and packed RBCs.

BACKGROUND:

Packed RBCs are supplied for transfusion by the first-in-first-out (FIFO) criterion, assuming that their quality is the same for packed RBCs with equal storage duration. To challenge this notion, we determined the deformability of F-RBC and packed RBCs stored for different durations.

METHODS:

Three RBC groups were employed A. 79 samples of F-RBC; B. 76 samples of packed RBC units, randomly used for transfusion at different storage durations; and C. 65 samples of outdated packed RBCs stored for 35 to 37 days. All packed RBC units were non-leukofiltrated and stored in Citrate-phosphate-dextrose solution with adenine (CPDA-1). RBC deformability was determined using a computerised cell-flow properties analyser, which monitors the shape change of cells directly visualised in a narrow-gap flow chamber and provides the cells' deformability distribution in a large RBC population.

RESULTS:

The F-RBC deformability exhibited a wide-range inter-donor variability. The cold storage of packed RBCs exerted a mild reduction of deformability, which became significant, compared to the initial inter-donor variability, only after 3 weeks of storage.

CONCLUSION:

Packed RBCs are generally supplied for transfusion by the FIFO criterion based on the assumption that the storage duration is a key factor of RBC quality. This study demonstrates that the deformability of red blood cells is significantly different in donors, and substantial variability persists throughout the entire process of their storage. Therefore, the FIFO criterion is not sufficient for assessing the RBC deformability, which should, therefore, be specifically characterised for each unit.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doadores de Sangue / Preservação de Sangue / Deformação Eritrocítica / Eritrócitos Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doadores de Sangue / Preservação de Sangue / Deformação Eritrocítica / Eritrócitos Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article