Your browser doesn't support javascript.
loading
Third-generation iterative reconstruction on a dual-source, high-pitch, low-dose chest CT protocol with tin filter for spectral shaping at 100 kV: a study on a small series of COVID-19 patients.
Agostini, Andrea; Borgheresi, Alessandra; Carotti, Marina; Ottaviani, Letizia; Badaloni, Myriam; Floridi, Chiara; Giovagnoni, Andrea.
Afiliação
  • Agostini A; Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, Ancona, Italy.
  • Borgheresi A; Department of Radiology, Division of Special and Pediatric Radiology, University Hospital "Umberto I - Lancisi - Salesi", Via Conca 71, 60126, Ancona, AN, Italy.
  • Carotti M; Department of Radiology, Division of Special and Pediatric Radiology, University Hospital "Umberto I - Lancisi - Salesi", Via Conca 71, 60126, Ancona, AN, Italy. alessandra.borgheresi@gmail.com.
  • Ottaviani L; Department of Clinical, Special and Dental Sciences, University Politecnica delle Marche, Ancona, Italy.
  • Badaloni M; Department of Radiology, Division of Special and Pediatric Radiology, University Hospital "Umberto I - Lancisi - Salesi", Via Conca 71, 60126, Ancona, AN, Italy.
  • Floridi C; Department of Radiology, Division of Special and Pediatric Radiology, University Hospital "Umberto I - Lancisi - Salesi", Via Conca 71, 60126, Ancona, AN, Italy.
  • Giovagnoni A; Department of Radiology, Division of Special and Pediatric Radiology, University Hospital "Umberto I - Lancisi - Salesi", Via Conca 71, 60126, Ancona, AN, Italy.
Radiol Med ; 126(3): 388-398, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33044732
OBJECTIVES: To investigate the role of third-generation iterative reconstruction (ADMIRE) in dual-source, high-pitch chest CT protocol with spectral shaping at 100 kVp in Coronavirus disease 2019 (COVID-19). METHODS: Confirmed COVID-19 inpatients undergoing to unenhanced chest CT were scanned with a dual-energy acquisition (DECT, 90/150Sn kV) and a dual-source, high-pitch acquisition with tin-filtered 100 kVp (LDCT). On the DECT with ADMIRE 3 (DECT3) were evaluated the pulmonary findings and their extension (25-point score). Two radiologists in consensus evaluated with 5-point scales the overall image quality, the anatomical structures, and the elementary findings on LDCT reconstructed with filtered backprojection (LDCT0), with ADMIRE 3 (LDCT3) and 5 (LDCT5), and on DECT3. The signal-to-noise ratio (SNR), the body mass index, the exposure times, and the radiation doses were recorded. RESULTS: Seventy-five patients (57 M/18F; median age: 63 y.o.) were included, with median pulmonary extension of 13/25 points. The imaging findings were detected in proportion comparable to the available literature. The ADMIRE significantly improved the SNR in LDCT (p < 0.00001) with almost no significant differences in overweight patients. The LDCT had median effective dose of 0.39 mSv and acquisition time of 0.71 s with significantly less motion artifacts than DECT (p < 0.00001). The DECT3 and LDCT3 provided the best image quality and depiction of pulmonary anatomy and imaging findings, with significant differences among all the series (p < 0.00001). CONCLUSION: The LDCT with spectral shaping and ADMIRE3 provided acceptable image quality in the evaluation of patients with COVID-19, with significantly reduced radiation dose and motion artifacts.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Tomografia Computadorizada por Raios X / COVID-19 / Pulmão Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Tomografia Computadorizada por Raios X / COVID-19 / Pulmão Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article