Your browser doesn't support javascript.
loading
Changes and impacts in early recurrences after atrial fibrillation ablation in contact force era: comparison of high-power short-duration with conventional technique-FIRST experience data.
Vassallo, Fabricio; Meigre, Lucas Luis; Serpa, Eduardo; Cunha, Christiano; Simoes, Aloyr; Carloni, Hermes; Amaral, Dalton; Meira, Karla; Pezzin, Flávia.
Afiliação
  • Vassallo F; Institute of Cardiology Espirito Santo, Rua Taciano Abaurre n. 225. 7 and 8th floors. Enseada do Sua, Vitória, Espírito Santo, 29050-470, Brazil. fabricio@arritmiaes.org.
  • Meigre LL; Santa Rita de Cassia Hospital, Vitoria, Brazil. fabricio@arritmiaes.org.
  • Serpa E; Santa Casa de Misericórdia Hospital, Porto Alegre, Brazil. fabricio@arritmiaes.org.
  • Cunha C; Institute of Cardiology Espirito Santo, Rua Taciano Abaurre n. 225. 7 and 8th floors. Enseada do Sua, Vitória, Espírito Santo, 29050-470, Brazil.
  • Simoes A; Institute of Cardiology Espirito Santo, Rua Taciano Abaurre n. 225. 7 and 8th floors. Enseada do Sua, Vitória, Espírito Santo, 29050-470, Brazil.
  • Carloni H; Santa Rita de Cassia Hospital, Vitoria, Brazil.
  • Amaral D; Santa Casa de Misericórdia Hospital, Porto Alegre, Brazil.
  • Meira K; Santa Rita de Cassia Hospital, Vitoria, Brazil.
  • Pezzin F; Santa Casa de Misericórdia Hospital, Porto Alegre, Brazil.
J Interv Card Electrophysiol ; 62(2): 363-371, 2021 Nov.
Article em En | MEDLINE | ID: mdl-33151444
ABSTRACT
BACKGROUND OR

PURPOSE:

Different atrial tachyarrhythmias (AT) may be seen during follow-up after atrial fibrillation ablation. Evaluate and analyze characteristics and management of AT following first atrial fibrillation (AF) ablation with high-power short-duration (HPSD) comparing to low-power long-duration (LPLD) and its impact on late outcome.

METHODS:

Observational, retrospective study, 144 patients submitted to HPSD and LPLD ablation. HPSD with 71 and LPLD with 73 patients and no major clinical differences between the two groups.

RESULTS:

AT occurred in 60 patients (41.67%) in entire follow-up. HPSD 22 patients had AT 13 during blanking period (BP) and 9 after that. LPLD 38 patients with AT, 14 during BP and 24 after that. During BP, HPSD showed high rate of atrial flutter/tachycardia in 9 (69.23) of 13 and LPLD 4 (28.57%) of 14 patients. At 12 months' follow-up, 62 (87.32%) of 71 HPSD patients were in sinus rhythm comparing to 49 (67.12%) of 73 patients in LPLD.

CONCLUSIONS:

HPSD ablation produced higher rates of early than late recurrence comparing to LPLD. Regular tachyarrhythmias were most common arrhythmia during BP with HPSD ablation and AF in LPLD. HPSD compared to LPLD showed a superiority in maintaining sinus rhythm at 12 months.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ablação por Cateter Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ablação por Cateter Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article