Your browser doesn't support javascript.
loading
Quantitative Method for the Analysis of Ivacaftor, Hydroxymethyl Ivacaftor, Ivacaftor Carboxylate, Lumacaftor, and Tezacaftor in Plasma and Sputum Using Liquid Chromatography With Tandem Mass Spectrometry and Its Clinical Applicability.
Vonk, Steffie E M; van der Meer-Vos, Marloes; Bos, Lieuwe D J; Neerincx, Anne H; Majoor, Christof J; Maitland-van der Zee, Anke-Hilse; Mathôt, Ron A A; Kemper, E Marleen.
Afiliação
  • Vonk SEM; Departments of Hospital Pharmacy.
  • van der Meer-Vos M; Departments of Hospital Pharmacy.
  • Bos LDJ; Respiratory Medicine, and.
  • Neerincx AH; Intensive Care, Amsterdam University Medical Centers, Amsterdam, the Netherlands .
  • Majoor CJ; Respiratory Medicine, and.
  • Maitland-van der Zee AH; Respiratory Medicine, and.
  • Mathôt RAA; Respiratory Medicine, and.
  • Kemper EM; Departments of Hospital Pharmacy.
Ther Drug Monit ; 43(4): 555-563, 2021 08 01.
Article em En | MEDLINE | ID: mdl-33165217
ABSTRACT

BACKGROUND:

The novel cystic fibrosis transmembrane conductance regulator (CFTR) modulators, ivacaftor, lumacaftor, and tezacaftor, are the first drugs directly targeting the underlying pathophysiological mechanism in cystic fibrosis (CF); however, independent studies describing their pharmacokinetics are lacking. The aim of this study was to develop a quantification method for ivacaftor and its 2 main metabolites, lumacaftor and tezacaftor, in plasma and sputum using liquid chromatography with tandem mass spectrometry.

METHODS:

The developed method used a small sample volume (20 µL) and simple pretreatment method; protein precipitation solution and internal standard were added in one step to each sample. Liquid chromatography with tandem mass spectrometry was performed for a total run time of 6 minutes. The method was validated by assessing selectivity, carryover, linearity, accuracy and precision, dilution, matrix effects, and stability.

RESULTS:

The selectivity was good as no interference from matrices was observed. In the concentration range from 0.01 to 10.0 mg/L, calibration curves were linear with a correlation coefficient >0.9997 for all compounds. The within-run and between-run accuracy were between 99.7% and 116% at the lower limit of quantitation (LLOQ) and between 95.8% and 112.9% for all concentrations above LLOQ for all analytes in plasma and sputum. Within-run and between-run precisions were <12.7% for LLOQ and <6.7% for the higher limit of quantitation. Samples were stable, with no significant degradation at examined temperatures and time points. Clinical applicability was revealed by analyzing samples from 2 patients with CF.

CONCLUSIONS:

The presented method enables simultaneous quantification of ivacaftor, lumacaftor, and tezacaftor in plasma and sputum and is an improvement over previous methods because it uses smaller sample volumes, a simple pretreatment protocol, and includes tezacaftor. In future studies, it can be applied for examining pharmacokinetics characteristics of new CF transmembrane conductance regulator modulators.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Quinolonas / Benzodioxóis / Aminofenóis / Aminopiridinas / Indóis Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Quinolonas / Benzodioxóis / Aminofenóis / Aminopiridinas / Indóis Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article