Your browser doesn't support javascript.
loading
The Colon Endoscopic Bubble Scale (CEBuS): a two-phase evaluation study.
Taveira, Filipe; Hassan, Cesare; Kaminski, Michal F; Ponchon, Thierry; Benamouzig, Robert; Bugajski, Marek; de Castelbajac, Flore; Cesaro, Paola; Chergui, Hasnae; Goran, Loredana; Minelli Grazioli, Leonardo; Janicko, Martin; Januszewicz, Wladyslaw; Lamonaca, Laura; Lenz, Jamila; Negreanu, Lucian; Repici, Alessandro; Spada, Cristiano; Spadaccini, Marco; State, Monica; Szlak, Jakub; Veseliny, Eduard; Dinis-Ribeiro, Mário; Areia, Miguel.
Afiliação
  • Taveira F; Department of Gastroenterology, Portuguese Oncology Institute of Coimbra, Coimbra, Portugal.
  • Hassan C; Gastroenterology and Digestive Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome, Italy.
  • Kaminski MF; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland.
  • Ponchon T; Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Center for Postgraduate Education, Warsaw, Poland.
  • Benamouzig R; Department of Cancer Prevention, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland.
  • Bugajski M; Department of Health Management and Health Economics, University of Oslo, Oslo, Norway.
  • de Castelbajac F; Department of Hepatogastroenterology, Hôpital Edouard Herriot, Lyon, France.
  • Cesaro P; Service de Gastroentérologie, Hôpital Avicenne (APHP), Bobigny, France.
  • Chergui H; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland.
  • Goran L; Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Center for Postgraduate Education, Warsaw, Poland.
  • Minelli Grazioli L; Service de Gastroentérologie, Hôpital Avicenne (APHP), Bobigny, France.
  • Janicko M; Digestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza, Brescia, Italy.
  • Januszewicz W; Service de Gastroentérologie, Hôpital Avicenne (APHP), Bobigny, France.
  • Lamonaca L; Department of Gastroenterology, University Hospital, 'Carol Davila' University Bucharest, Romania.
  • Lenz J; Digestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza, Brescia, Italy.
  • Negreanu L; 2nd Department of Internal Medicine, Pavol Jozef Safárik University, Kosice, Slovakia.
  • Repici A; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland.
  • Spada C; Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Center for Postgraduate Education, Warsaw, Poland.
  • Spadaccini M; Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS -, Rozzano, Lombardia, Italy.
  • State M; Department of Hepatogastroenterology, Hôpital Edouard Herriot, Lyon, France.
  • Szlak J; Department of Gastroenterology, University Hospital, 'Carol Davila' University Bucharest, Romania.
  • Veseliny E; Endoscopy Unit, Humanitas Clinical and Research Center - IRCCS -, Rozzano, Lombardia, Italy.
  • Dinis-Ribeiro M; Digestive Endoscopy Unit and Gastroenterology, Fondazione Poliambulanza, Brescia, Italy.
  • Areia M; Digestive Endoscopy Unit, Università Cattolica del Sacro Cuore, Rome, Italy.
Endoscopy ; 54(1): 45-51, 2022 01.
Article em En | MEDLINE | ID: mdl-33285583
ABSTRACT

BACKGROUND:

To date, no scale has been validated to assess bubbles associated with bowel preparation. This study aimed to develop and assess the reliability of a novel scale - the Colon Endoscopic Bubble Scale (CEBuS).

METHODS:

This was a multicenter, prospective, observational study with two online evaluation phases of 45 randomly distributed still colonoscopy images (15 per scale grade). Observers assessed images twice, 2 weeks apart, using CEBuS (CEBuS-0 - no or minimal bubbles, covering < 5 % of the surface; CEBuS-1 - bubbles covering 5 %-50 %; CEBuS-2 - bubbles covering > 50 %) and reporting the clinical action (do nothing; wash with water; wash with simethicone).

RESULTS:

CEBuS provided high levels of agreement both in evaluation Phase 1 (4 experts) and Phase 2 (6 experts and 13 non-experts), with almost perfect intraobserver reliability kappa 0.82 (95 % confidence interval 0.75-0.88) and 0.86 (0.85-0.88); interobserver agreement - intraclass correlation coefficient (ICC) 0.83 (0.73-0.89) and 0.90 (0.86-0.94). Previous endoscopic experience had no influence on agreement among experts vs. non-experts kappa 0.86 (0.80-0.91) vs. 0.87 (0.84-0.89) and ICC 0.91 (0.87-0.94) vs. 0.90 (0.86-0.94), respectively. Interobserver agreement on clinical action was ICC 0.63 (0.43-0.78) in Phase 1 and 0.77 (0.68-0.84) in Phase 2. Absolute agreement on clinical action per scale grade was 85 % (82-88) for CEBuS-0, 21 % (16-26) for CEBuS-1, and 74 % (70-78) for CEBuS-2.

CONCLUSION:

CEBuS proved to be a reliable instrument to standardize the evaluation of colonic bubbles during colonoscopy. Assessment in daily practice is warranted.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Simeticone / Colonoscopia Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Simeticone / Colonoscopia Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article