Your browser doesn't support javascript.
loading
Test-Retest-Reliability of Computer-Based Metamorphopsia Measurement in Macular Diseases. / Test-Retest-Reliabilität der computergestützten Metamorphopsiemessung bei Makulaerkrankungen.
Claessens, Daniela; Schuster, Alexander K; Krüger, Ronald V; Liegl, Marian; Singh, Laila; Kirchhof, Bernd.
Afiliação
  • Claessens D; Gemeinschaftspraxis Augenheilkunde Lindenthal, Köln, Deutschland.
  • Schuster AK; Augenklinik, Universitätsmedizin Mainz, Deutschland.
  • Krüger RV; Development, app4eyes GmbH & Co KG, Düsseldorf, Deutschland.
  • Liegl M; Humanmedizinische Fakultät, Universität zu Köln, Deutschland.
  • Singh L; Max-Planck-Institut für Biologie des Alterns, Köln, Deutschland.
  • Kirchhof B; Abteilung für Netzhaut- und Glaskörper-Chirurgie, Zentrum für Augenheilkunde, Universität zu Köln, Deutschland.
Klin Monbl Augenheilkd ; 238(6): 703-710, 2021 Jun.
Article em En, De | MEDLINE | ID: mdl-33285595
ABSTRACT
In this study, the test-retest-reliability as one aspect of reliability of metamorphopsia measurements using a computer-based measuring method was determined in patients with macular diseases. Metamorphopsia amplitude, position, and area were quantified using AMD - A Metamorphopsia Detector software (app4eyes GmbH & Co. KG, Germany) in patients with diabetic, myopic, or uveitic macular edema, intermediate or neovascular age-associated macular degeneration, epiretinal membrane, vitelliform maculopathy, Irvine-Gass syndrome, or macular edema due to venous retinal occlusion. The intraclass correlation coefficient (ICC) was calculated in order to determine the repeatability of two repeated measurements and was used as an indicator of the reliability of the measurements. In this study, metamorphopsia measurements were conducted on 36 eyes with macular diseases. Metamorphopsia measurements made using AMD - A Metamorphopsia Detector software were highly reliable and repeatable in patients with maculopathies. The intraclass correlation coefficient of all indices was excellent (0.95 - 0.97). For diseases of the vitreoretinal interface or macular diseases with intra- or subretinal edema, this metamorphopsia measurement represents a supplement for visual function testing in the clinic, as well as in clinical studies.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transtornos da Visão / Computadores Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Humans País como assunto: Europa Idioma: De / En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transtornos da Visão / Computadores Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Humans País como assunto: Europa Idioma: De / En Ano de publicação: 2021 Tipo de documento: Article