Your browser doesn't support javascript.
loading
Validation of a QuEChERS method for extraction of estrogens from a complex water matrix and quantitation via high-performance liquid chromatography-mass spectrometry.
Sweeney, Crystal L; Bennett, Jessica L; Brown, Clarke A M; Ross, Neil W; Gagnon, Graham A.
Afiliação
  • Sweeney CL; Centre for Water Resources Studies, Department of Civil and Resource Engineering, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada.
  • Bennett JL; Centre for Water Resources Studies, Department of Civil and Resource Engineering, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada.
  • Brown CAM; Centre for Water Resources Studies, Department of Civil and Resource Engineering, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada; Department of Biology, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada.
  • Ross NW; Department of Biology, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada; NovaEel Inc., 2161, Armcrescent Drive, Halifax, Nova Scotia, B3L 3C8, Canada.
  • Gagnon GA; Centre for Water Resources Studies, Department of Civil and Resource Engineering, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada. Electronic address: graham.gagnon@dal.ca.
Chemosphere ; 263: 128315, 2021 Jan.
Article em En | MEDLINE | ID: mdl-33297250
ABSTRACT
The traditional approach to extracting estrogens from water matrices, solid-phase extraction (SPE), presents a number of challenges when applied to complex wastewater matrices. Conversely, the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) clean-up method offers an alternative sample preparation approach that omits sample filtration and overcomes additional challenges associated with SPE. The objective of this study was to implement and validate a scaled QuEChERS method, using a standard addition approach, for extracting estrone (E1), 17ß-estradiol (E2), and estriol (E3) from the estrogenic influent of a recirculating aquaculture system containing American eels (Anguilla rostrata). While traditional QuEChERS protocols do not facilitate considerable sample concentration, a 500-fold concentration factor was implemented for reliable quantitation of parts-per-trillion concentrations of estrogens from an initial sample volume of 20 mL to a final extract volume of 40 µL. Following analysis via high-performance liquid chromatography-mass spectrometry, excellent process efficiencies were observed at spiked concentrations of 10 and 50 ng L-1 for E2 and E1 (101 to 111%; %RSD ≤ 16), and moderate to acceptable process efficiencies were achieved for E3 (75 to 87%; %RSD ≤ 16). Validation of method parameters, including specificity, linearity, accuracy (recovery and process efficiencies), precision (intra-day precision, and inter-day precision), matrix effects, method detection limit, and limit of quantitation, led to reliable quantitation of unknown concentrations of E1, E2, and E3 in the aquaculture influent as low as 52, 20, and 33 ng L-1, respectively. This study provides a validated analytical method for waste systems requiring quantitation of estrogens in their complex wastewater matrices.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Água / Estrogênios Idioma: En Ano de publicação: 2021 Tipo de documento: Article