Your browser doesn't support javascript.
loading
Glucose-Functionalized Liposomes for Reducing False Positives in Cancer Diagnosis.
Tzror-Azankot, Chen; Betzer, Oshra; Sadan, Tamar; Motiei, Menachem; Rahimipour, Shai; Atkins, Ayelet; Popovtzer, Aron; Popovtzer, Rachela.
Afiliação
  • Tzror-Azankot C; Faculty of Engineering and the Institute of Nanotechnology & Advanced Materials, Bar-Ilan University, Ramat Gan 5290002, Israel.
  • Betzer O; Faculty of Engineering and the Institute of Nanotechnology & Advanced Materials, Bar-Ilan University, Ramat Gan 5290002, Israel.
  • Sadan T; Faculty of Engineering and the Institute of Nanotechnology & Advanced Materials, Bar-Ilan University, Ramat Gan 5290002, Israel.
  • Motiei M; Faculty of Engineering and the Institute of Nanotechnology & Advanced Materials, Bar-Ilan University, Ramat Gan 5290002, Israel.
  • Rahimipour S; Department of Chemistry, Bar-Ilan University, Ramat Gan 5290002, Israel.
  • Atkins A; Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan University, Ramat Gan, 5290002, Israel.
  • Popovtzer A; Sharett Institute of Oncology, Hadassah Hebrew Medical Center, Jerusalem 9112001, Israel.
  • Popovtzer R; Faculty of Engineering and the Institute of Nanotechnology & Advanced Materials, Bar-Ilan University, Ramat Gan 5290002, Israel.
ACS Nano ; 15(1): 1301-1309, 2021 01 26.
Article em En | MEDLINE | ID: mdl-33356143
Fluorodeoxyglucose-positron emission tomography (18F-FDG-PET) is a powerful tool for cancer detection, staging, and follow-up. However, 18F-FDG-PET imaging has high rates of false positives, as it cannot distinguish between tumor and inflammation regions that both feature increased glucose metabolic activity. In the present study, we engineered liposomes coated with glucose and the chelator dodecane tetraacetic acid (DOTA) complexed with copper, to serve as a diagnostic technology for differentiating between cancer and inflammation. This liposome technology is based on FDA-approved materials and enables complexation with metal cations and radionuclides. We found that these liposomes were preferentially uptaken by cancer cell lines with high metabolic activity, mediated via glucose transporter-1. In vivo, these liposomes were avidly uptaken by tumors, as compared to liposomes without glucose coating. Moreover, in a combined tumor-inflammation mouse model, these liposomes accumulated in the tumor tissue and not in the inflammation region. Thus, this technology shows high specificity for tumors while evading inflammation and has potential for rapid translation to the clinic and integration with existing PET imaging systems, for effective reduction of false positives in cancer diagnosis.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lipossomos / Neoplasias Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lipossomos / Neoplasias Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article