Your browser doesn't support javascript.
loading
Efficacy and safety of atrial septal defect closure using Occlutech Figulla Flex II compared with Amplatzer Septal Occluder.
Nakayama, Rie; Takaya, Yoichi; Akagi, Teiji; Watanabe, Nobuhisa; Miki, Takashi; Nakagawa, Koji; Toh, Norihisa; Ito, Hiroshi.
Afiliação
  • Nakayama R; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan.
  • Takaya Y; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan. takayayoichi@okayama-u.ac.jp.
  • Akagi T; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan.
  • Watanabe N; Division of Medical Support, Okayama University Hospital, Okayama, Japan.
  • Miki T; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan.
  • Nakagawa K; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan.
  • Toh N; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan.
  • Ito H; Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science, 2-5-1 Shikata-cho, Kita-ku, Okayama, 700-8558, Japan.
Heart Vessels ; 36(5): 704-709, 2021 May.
Article em En | MEDLINE | ID: mdl-33386412
Few studies have reported the efficacy of Occlutech Figulla Flex II (FFII) device compared with Amplatzer Septal Occluder (ASO) device. The aim of this study was to examine the efficacy and safety of FFII compared with ASO for transcatheter atrial septal defect (ASD) closure. We retrospectively evaluated 190 patients using FFII and 190 patients using ASO who underwent transcatheter ASD closure. ASD characteristics were evaluated by transesophageal echocardiography. The prevalence of procedural complications, including erosion, device embolization, stroke, and new-onset atrial arrhythmia, and the presence of a residual shunt were evaluated between the two groups during 12-month follow-up. FFII was used more frequently than ASO in patients with a deficient aortic rim or septal malalignment (P = 0.02, P < 0.01, respectively). The procedural complications of erosion, device embolization, and stroke did not occur in any patients. New-onset atrial arrhythmia occurred in 3 patients of the FFII group and 4 patients of the ASO group, and the difference between the two groups was not significant (P = 0.70). A large residual shunt (≥ 3 mm) was observed in 6 patients of the FFII group and 5 patients of the ASO group, and the difference between the two groups was not significant (P = 0.76). FFII was used frequently in patients with high-risk ASD morphology; however, there was no difference in the prevalence of procedural complications or efficacy between patients using FFII and those using ASO.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Cardíaco / Dispositivo para Oclusão Septal / Comunicação Interatrial Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Cardíaco / Dispositivo para Oclusão Septal / Comunicação Interatrial Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article