Your browser doesn't support javascript.
loading
A validated liquid chromatography tandem mass spectrometry assay for the analysis of pretomanid in plasma samples from pulmonary tuberculosis patients.
Malo, Andisiwe; Kellermann, Tracy; Ignatius, Elisa H; Dooley, Kelly E; Dawson, Rodney; Joubert, Anton; Norman, Jennifer; Castel, Sandra; Wiesner, Lubbe.
Afiliação
  • Malo A; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa. Electronic address: mlxand007@myuct.ac.za.
  • Kellermann T; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa; Division of Clinical Pharmacology, Department of Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.
  • Ignatius EH; Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • Dooley KE; Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • Dawson R; Division of Pulmonology, Department of Medicine, University of Cape Town Lung Institute, Cape Town, South Africa.
  • Joubert A; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa.
  • Norman J; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa.
  • Castel S; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa.
  • Wiesner L; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa.
J Pharm Biomed Anal ; 195: 113885, 2021 Feb 20.
Article em En | MEDLINE | ID: mdl-33406472
A method for the extraction and quantification of pretomanid in 40 µL of human plasma, by high performance liquid chromatography with tandem mass spectrometry (LC-MS/MS) detection was developed and validated. Samples were prepared using liquid-liquid extraction and chromatographic separation was achieved on an Agilent Poroshell C18 column using an isocratic elution at a flow rate of 400 µL/min. Electrospray ionization with mass detection at unit resolution in the multiple reaction monitoring (MRM) mode on an AB Sciex API 3200 mass spectrometer was used. Over the validation period, accuracy, precision, selectivity, sensitivity, recovery and stability were assessed. The calibration range was 10 - 10 000 ng/mL. Inter- and intra-day precision, expressed as the coefficient of variation (%CV), was shown to be lower than 9% at all concentrations tested with accuracies between 95.2 and 110 %. The recovery was 72.4 % overall and reproducible at the low, medium and high end of the calibration range. The method was shown to be specific for pretomanid with no significant matrix effects observed. The validated method facilitated the analysis of pretomanid in plasma collected from adults with pulmonary TB as part of a clinical pharmacokinetic study.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tuberculose Pulmonar / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tuberculose Pulmonar / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article