Your browser doesn't support javascript.
loading
[Optimal Mono-energy in Mono-energetic Spectral Computed Tomography of Enhanced Renal Cortex in Cortical Phase Based on Iodine Concentration].
Meng, Qing Lin; Zong, Lin Xiong; Liu, Meng Qi; Wang, Ping Huai; Chen, Zhi Ye.
Afiliação
  • Meng QL; Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China.
  • Zong LX; Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China.
  • Liu MQ; Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China.
  • Wang PH; Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China.
  • Chen ZY; Department of Radiology,Hainan Hospital of Chinese PLA General Hospital,Sanya,Hainan 572013,China.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 42(6): 776-780, 2020 Dec 30.
Article em Zh | MEDLINE | ID: mdl-33423725
ABSTRACT
Objective To identify the optimal mono-energetic enhanced spectral CT for renal cortex in cortical phase based on the iodine concentration. Methods Fifty patients with normal renal function received the abdominal enhanced spectral CT examination.The iodine concentration and CT values of the multiple mono-energetic spectral images were measured on renal cortex in cortical phase,and the correlation between the iodine concentration and the CT values and the coefficient of variation(CV)were analyzed. Results The correlation analysis demonstrated that the correlation coefficient was 0.994,0.994,0.993,0.987,0.976,0.960,and 0.938 between mono-energetic spectral CT images(40-100 keV with interval 10 keV,respectively)and iodine concentration(all P <0.001).The correlation coefficients of 40 keV,50 keV(P=0.007)and 60 keV(P=0.030)were significantly higher compared with that of 70 keV,and the correlation coefficients were not significantly among 40 keV,50 keV and 60 keV(P =0.590).The CV of renal cortex in cortical phase was 0.21,0.20,and 0.19 for 40 keV,50 keV,and 60 keV,respectively. Conclusion 60 keV is the optimal mono-energy for the enhanced spectral CT of the renal cortex in cortical phase.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Meios de Contraste / Iodo / Córtex Renal Limite: Humans Idioma: Zh Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Meios de Contraste / Iodo / Córtex Renal Limite: Humans Idioma: Zh Ano de publicação: 2020 Tipo de documento: Article