Your browser doesn't support javascript.
loading
Spectral diffusion analysis of kidney intravoxel incoherent motion MRI in healthy volunteers and patients with renal pathologies.
Stabinska, Julia; Ljimani, Alexandra; Zöllner, Helge Jörn; Wilken, Enrica; Benkert, Thomas; Limberg, Juliane; Esposito, Irene; Antoch, Gerald; Wittsack, Hans-Jörg.
Afiliação
  • Stabinska J; Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany.
  • Ljimani A; Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany.
  • Zöllner HJ; Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany.
  • Wilken E; Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.
  • Benkert T; F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA.
  • Limberg J; Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany.
  • Esposito I; MR Application Development, Siemens Healthcare GmbH, Erlangen, Germany.
  • Antoch G; Institute of Pathology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany.
  • Wittsack HJ; Institute of Pathology, Medical Faculty, Heinrich Heine University Dusseldorf, Düsseldorf, Germany.
Magn Reson Med ; 85(6): 3085-3095, 2021 06.
Article em En | MEDLINE | ID: mdl-33462838
ABSTRACT

PURPOSE:

To assess the feasibility of measuring tubular and vascular signal fractions in the human kidney using nonnegative least-square (NNLS) analysis of intravoxel incoherent motion data collected in healthy volunteers and patients with renal pathologies.

METHODS:

MR imaging was performed at 3 Tesla in 12 healthy subjects and 3 patients with various kidney pathologies (fibrotic kidney disease, failed renal graft, and renal masses). Relative signal fractions f and mean diffusivities of the diffusion components in the cortex, medulla, and renal lesions were obtained using the regularized NNLS fitting of the intravoxel incoherent motion data. Test-retest repeatability of the NNLS approach was tested in 5 volunteers scanned twice.

RESULTS:

In the healthy kidneys, the NNLS method yielded diffusion spectra with 3 distinguishable components that may be linked to the slow tissue water diffusion, intermediate tubular and vascular flow, and fast blood flow in larger vessels with the relative signal fractions, fslow , finterm and ffast , respectively. In the pathological kidneys, the diffusion spectra varied substantially from those acquired in the healthy kidneys. Overall, the renal cyst showed substantially higher finterm and lower fslow , whereas the fibrotic kidney, failed renal graft, and renal cell carcinoma demonstrated the opposite trend.

CONCLUSION:

NNLS-based intravoxel incoherent motion could potentially become a valuable tool in assessing changes in tubular and vascular volume fractions under pathophysiological conditions.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem de Difusão por Ressonância Magnética / Rim Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem de Difusão por Ressonância Magnética / Rim Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article