Maxillary expansion or contraction and occlusal contact adjustment: effectiveness of current aligner treatment.
Riede, Ulrike; Wai, Sandra; Neururer, Sabrina; Reistenhofer, Bärbel; Riede, Gregor; Besser, Katharina; Crismani, Adriano.
Afiliação
  • Riede U; Department of Orthodontics, Medical University of Innsbruck, Innsbruck, Austria. ulrike.palenberg@i-med.ac.at.
  • Wai S; Department of Orthodontics, Medical University of Innsbruck, Innsbruck, Austria.
  • Neururer S; Department of Medical Statistics, Informatics and Health Economics, Medical University of Innsbruck, Innsbruck, Austria.
  • Reistenhofer B; Private Practice of Orthodontics, Vienna, Austria.
  • Riede G; Private Practice of Oral and Maxillofacial Surgery, Jenbach, Austria.
  • Besser K; Private Practice of Orthodontics, Vienna, Austria.
  • Crismani A; Department of Orthodontics, Medical University of Innsbruck, Innsbruck, Austria.
Clin Oral Investig ; 25(7): 4671-4679, 2021 Jul.
Article em En | MEDLINE | ID: mdl-33474622
ABSTRACT

OBJECTIVES:

To evaluate the precision of aligner (Invisalign®) treatment with the current material (SmartTrack®) in achieving expansion or contraction of the maxilla and occlusal contacts as simulated in the proprietary planning software (ClinCheck®, CC). MATERIALS AND

METHODS:

Thirty patients thus treated were retrospectively evaluated. Four maxillary models were analyzed per patient a pretreatment model, a scan-based CC model, a posttreatment clinical model, and a CC model reflecting the treatment outcome as initially simulated. Thirteen transverse parameters were measured on each model separately by two investigators. Occlusal contacts were also analyzed.

RESULTS:

The measuring method was validated by both investigators arriving at similar results for the effectiveness by which the simulated treatment goals had been clinically achieved. Significant differences (p < 0.05; Wilcoxon signed-rank test) were observed for transfer precision from the casts to the planning software and between the simulated and clinical outcomes. Intense occlusal contacts in the simulations materialized less common (≈ 2%) than ideal contacts (≈ 60%) in the clinical outcomes.

CONCLUSIONS:

The effectiveness of achieving the simulated transverse goals was 45% and was generally not found to be better with SmartTrack® than with the previously used Ex30® material. Out of 100 simulated occlusal contacts, 40 will never materialize, and achieving around 60 will adequately ensure a clinically favorable contact pattern. CLINICAL RELEVANCE With the caveat that any overcorrection will to some extent reduce the precision, it seems perfectly possible to make deliberate use of overcorrection in current aligner therapies for transverse maxillary expansion or contraction.