Your browser doesn't support javascript.
loading
Online Microdialysis-High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry (MD-HPLC-ICP-MS) as a Novel Tool for Sampling Hexavalent Chromium in Soil Solution.
Hamilton, Elliott M; Young, Scott D; Bailey, Elizabeth H; Humphrey, Olivier S; Watts, Michael J.
Afiliação
  • Hamilton EM; Inorganic Geochemistry, Centre for Environmental Geochemistry, British Geological Survey, Keyworth, Nottingham NG12 5GG, U.K.
  • Young SD; School of Biosciences, University of Nottingham, Sutton Bonington Campus, Leicestershire LE12 5RD, U.K.
  • Bailey EH; School of Biosciences, University of Nottingham, Sutton Bonington Campus, Leicestershire LE12 5RD, U.K.
  • Humphrey OS; School of Biosciences, University of Nottingham, Sutton Bonington Campus, Leicestershire LE12 5RD, U.K.
  • Watts MJ; Inorganic Geochemistry, Centre for Environmental Geochemistry, British Geological Survey, Keyworth, Nottingham NG12 5GG, U.K.
Environ Sci Technol ; 55(4): 2422-2429, 2021 02 16.
Article em En | MEDLINE | ID: mdl-33497200
ABSTRACT
Conventional soil solution sampling of species-sensitive inorganic contaminants, such as hexavalent chromium (CrVI), may induce interconversions due to disruption of system equilibrium. The temporal resolution that these sampling methods afford may also be insufficient to capture dynamic interactions or require time-consuming and expensive analysis. Microdialysis (MD) is emerging as a minimally invasive passive sampling method in environmental science, permitting the determination of solute fluxes and concentrations at previously unobtainable spatial scales and time frames. This article presents the first use of MD coupled to high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for the continuous sampling and simultaneous detection of CrVI in soil solution. The performance criteria of the system were assessed using stirred solutions; good repeatability of measurement (RSD < 2.5%) was obtained for CrVI, with a detection limit of 0.2 µg L-1. The online MD-HPLC-ICP-MS setup was applied to the sampling of native CrVI in three soils with differing geochemical properties. The system sampled and analyzed fresh soil solution at 15 min intervals, offering improved temporal resolution and a significant reduction in analysis time over offline MD. Simple modifications to the chromatographic conditions could resolve additional analytes, offering a powerful tool for the study of solute fluxes in soil systems to inform research into nutrient availability or soil-to-plant transfer of potentially harmful elements.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Solo / Cromo Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Solo / Cromo Idioma: En Ano de publicação: 2021 Tipo de documento: Article