Your browser doesn't support javascript.
loading
Increasing the fine particle fraction of pressurised metered dose inhaler solutions with novel actuator shapes.
Duke, Daniel J; Nguyen, Dung T; Dos Reis, Larissa Gomes; Silva, Dina M; Neild, Adrian; Edgington-Mitchell, Daniel; Young, Paul M; Honnery, Damon R.
Afiliação
  • Duke DJ; Laboratory for Turbulence Research in Aerospace & Combustion (LTRAC), Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Australia. Electronic address: daniel.duke@monash.edu.
  • Nguyen DT; Laboratory for Turbulence Research in Aerospace & Combustion (LTRAC), Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Australia.
  • Dos Reis LG; Respiratory Technology, Woolcock Institute of Medical Research and Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
  • Silva DM; Respiratory Technology, Woolcock Institute of Medical Research and Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
  • Neild A; Laboratory for Microsystems, Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Australia.
  • Edgington-Mitchell D; Laboratory for Turbulence Research in Aerospace & Combustion (LTRAC), Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Australia.
  • Young PM; Respiratory Technology, Woolcock Institute of Medical Research and Discipline of Pharmacology, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
  • Honnery DR; Laboratory for Turbulence Research in Aerospace & Combustion (LTRAC), Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Australia.
Int J Pharm ; 597: 120341, 2021 Mar 15.
Article em En | MEDLINE | ID: mdl-33545289
ABSTRACT
In this paper we demonstrate that the use of multiple orifices can improve the fine particle fraction (FPF) of pressurised metered-dose inhaler solution formulations by up to 75% when compared to a single orifice with an equivalent cross sectional area (p<0.05). While prior work has relied on metal actuator components, improvements in micro injection moulding and micro drilling now make it possible to mass produce novel orifice shapes to achieve similar FPF gains in plastic parts, with orifice diameters less than 0.2 mm. The ability to create internal features inside the actuator is also demonstrated. We show through in vitro high speed imaging that twin orifice sprays merge quickly and act as a single, modified plume. We also show for the first time that FPF and fine particle dose (FPD) are strongly correlated with the distance at which the plume velocity decays to half its initial value (R2=0.997 and 0.95 respectively). When plume velocity & FPF are increased, mouthpiece deposition decreases. This suggests that while smaller orifices produce more fine particles, higher sustained plume velocities also entrain more of the fine particles produced at the periphery of the spray due to increased shear. The effect occurs within the mouthpiece and is thus unlikely to alter the flow field in the upper airway.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nebulizadores e Vaporizadores / Inaladores Dosimetrados Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nebulizadores e Vaporizadores / Inaladores Dosimetrados Idioma: En Ano de publicação: 2021 Tipo de documento: Article