Your browser doesn't support javascript.
loading
A novel biosensor for the ultrasensitive detection of the lncRNA biomarker MALAT1 in non-small cell lung cancer.
Chen, Mei; Wu, Dongming; Tu, Shihua; Yang, Chaoyin; Chen, DeJie; Xu, Ying.
Afiliação
  • Chen M; Clinical Laboratory, Clinical Medical College and The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, Sichuan, People's Republic of China.
  • Wu D; School of Bioscience and Technology, Chengdu Medical College, Chengdu, 610500, Sichuan, People's Republic of China.
  • Tu S; Clinical Laboratory, Clinical Medical College and The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610500, Sichuan, People's Republic of China.
  • Yang C; School of Bioscience and Technology, Chengdu Medical College, Chengdu, 610500, Sichuan, People's Republic of China.
  • Chen D; School of Bioscience and Technology, Chengdu Medical College, Chengdu, 610500, Sichuan, People's Republic of China.
  • Xu Y; School of Bioscience and Technology, Chengdu Medical College, Chengdu, 610500, Sichuan, People's Republic of China.
Sci Rep ; 11(1): 3666, 2021 02 11.
Article em En | MEDLINE | ID: mdl-33574438
ABSTRACT
Long non-coding RNAs (lncRNAs) have been proposed as diagnostic biomarkers for the screening of non-small cell lung cancer and monitoring disease progression. Accordingly, new, rapid, and cost-effective lncRNA biosensors that can be used clinically are urgently needed. Herein, a novel effective and ultrasensitive electrochemical biosensor was developed based on a gold nanocage coupled with an amidated multi-walled carbon nanotube (Au NCs/MWCNT-NH2)-decorated screen-printed carbon electrode (SPCE). Because of its large surface area, superior conductivity, and excellent biocompatibility, this SPCE Au NCs/MWCNT-NH2 lncRNA biosensor showed a wide linear range (10-7-10-14 M) and low limit of detection limit (42.8 fM) coupled with satisfactory selectivity and stability. Compared to traditional RT-PCR, the proposed method exhibits acceptable stability, good selectivity, is simpler to operate, has faster detection, and uses less costly raw materials. In summary, this biosensor may be a powerful tool for detecting lncRNAs for efficient clinical prognosis and cancer diagnosis.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Carcinoma Pulmonar de Células não Pequenas / RNA Longo não Codificante Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Carcinoma Pulmonar de Células não Pequenas / RNA Longo não Codificante Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article