Your browser doesn't support javascript.
loading
A surrogate model for plaque modeling in carotids based on Robin conditions calibrated by cine MRI data.
Pozzi, Silvia; Domanin, Maurizio; Forzenigo, Laura; Votta, Emiliano; Zunino, Paolo; Redaelli, Alberto; Vergara, Christian.
Afiliação
  • Pozzi S; MOX, Department of Mathematics, Politecnico di Milano, Milan, Italy.
  • Domanin M; Department of Clinical Sciences and Community Health, Università di Milano, Milan, Italy.
  • Forzenigo L; Unità Operativa di Chirurgia Vascolare, Fondazione I.R.C.C.S. Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy.
  • Votta E; Unità Operativa di Radiologia, Fondazione I.R.C.C.S. Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy.
  • Zunino P; Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy.
  • Redaelli A; MOX, Department of Mathematics, Politecnico di Milano, Milan, Italy.
  • Vergara C; Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy.
Int J Numer Method Biomed Eng ; 37(5): e3447, 2021 05.
Article em En | MEDLINE | ID: mdl-33586336
ABSTRACT
We propose a surrogate model for the fluid-structure interaction (FSI) problem for the study of blood dynamics in carotid arteries in presence of plaque. This is based on the integration of a numerical model with subject-specific data and clinical imaging. We propose to model the plaque as part of the tissues surrounding the vessel wall through the application of an elastic support boundary condition. In order to characterize the plaque and other surrounding tissues, such as the close-by jugular vein, the elastic parameters of the boundary condition were spatially differentiated and their values were estimated by minimizing the discrepancies between computed vessel displacements and reference values obtained from CINE Magnetic Resonance Imaging data. We applied the model to three subjects with a degree of stenosis greater than 70%. We found that accounting for both plaque and jugular vein in the estimation of the elastic parameters increases the accuracy. In particular, in all patients, mismatches between computed and in vivo measured wall displacements were one to two orders of magnitude lower than the spatial resolution of the original MRI data. These results confirmed the validity of the proposed surrogate plaque model. We also compared fluid-dynamics results with those obtained in a fixed wall setting and in a full FSI model, used as gold standard, highlighting the better accordance of our results in comparison to the rigid ones.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aves Canoras / Placa Aterosclerótica Limite: Animals / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aves Canoras / Placa Aterosclerótica Limite: Animals / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article