Your browser doesn't support javascript.
loading
Stability indicating RP-HPLC method of dexibuprofen in nanocream formulation: Identification and quantification.
Munir, Rabia; Syed, Haroon Khalid; Asghar, Sajid; Iqbal, Muhammad Shahid; Irfan, Muhammad; Khan, Ikram Ullah; Shah, Pervaiz A; Khalid, Ikrima; Imran, Kashif; Saleem, Muhammad.
Afiliação
  • Munir R; Department of Pharmaceutics, Faculty of Pharmaceutical Sciences, Government College University, Faisalabad, Pakistan.
  • Syed HK; Department of Pharmaceutics, Faculty of Pharmaceutical Sciences, Government College University, Faisalabad, Pakistan.
  • Asghar S; Department of Pharmaceutics, Faculty of Pharmaceutical Sciences, Government College University, Faisalabad, Pakistan.
  • Iqbal MS; Department of Clinical Pharmacy, College of Pharmacy, Prince Sattam bin Abdulaziz University, Alkharj, Kingdom of Saudi Arabia.
  • Irfan M; Department of Pharmaceutics, Faculty of Pharmaceutical Sciences, Government College University, Faisalabad, Pakistan.
  • Khan IU; Department of Pharmaceutics, Faculty of Pharmaceutical Sciences, Government College University, Faisalabad, Pakistan.
  • Shah PA; University College of Pharmacy, University of the Punjab, Lahore, Pakistan.
  • Khalid I; Department of Pharmaceutics, Faculty of Pharmaceutical Sciences, Government College University, Faisalabad, Pakistan.
  • Imran K; Department of Pharmaceutics, Faculty of Pharmaceutical Sciences, Government College University, Faisalabad, Pakistan.
  • Saleem M; University College of Pharmacy, University of the Punjab, Lahore, Pakistan.
Pak J Pharm Sci ; 33(4(Supplementary)): 1815-1821, 2020 Jul.
Article em En | MEDLINE | ID: mdl-33612465
ABSTRACT
A stability indicating reverse phase-HPLC method was designed for determination of dexibuprofen in drug solution and in nanocream formulation. Chromatographic conditions were optimized simply by adjusting the content and different compositions of reverse phase associated with mobile phases. Different parameters like specificity, limit of quantification (LOQ), limit of detection, linearity, range, system suitability, precision and accuracy were determined. Stability studies of dexibuprofen in nanocream were taken under the stressed situations of alkali, acid, oxidation process, UV and heat degradation. Tailing factor and % RSD were found >2000 and <2% respectively. The method was identified linear over the range of 0.2-1.6mg/ml having co-efficient of correlation 0.9995. Intra-day and inter- day precision and accuracy values for dexibuprofen were < 0.6% and <1.1032 and < 0.3% and 1.10% respectively. Stability studies showed that dexibuprofen was stable in nanocream against alkali, acid, oxidation, UV light and heat. The developed validated method was precise and accurate for the evaluation of dexibuprofen in solution as well as in nanocream formulation.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Ibuprofeno / Cromatografia Líquida de Alta Pressão / Nanopartículas / Cromatografia de Fase Reversa Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Ibuprofeno / Cromatografia Líquida de Alta Pressão / Nanopartículas / Cromatografia de Fase Reversa Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article