His-Purkinje system longitudinal dissociation: From bench to bedside. A case of output-dependent fascicular capture.
J Cardiovasc Electrophysiol
; 32(4): 1174-1177, 2021 04.
Article
em En
| MEDLINE
| ID: mdl-33625765
ABSTRACT
INTRODUCTION:
Histological studies reported that the His bundle (HB) is partitioned into narrow cords by collagen running in its long axis, providing the anatomical setting necessary for its longitudinal dissociation. Further confirmations came from the demonstration that direct HB pacing normalizes the QRS axis and duration in subjects with proximal HB lesions causing bundle branch block. However, there is no evidence of the possibility of selective HB partitions pacing destined to the composition of branches and fascicles. METHODS ANDRESULTS:
We describe a case of intra-Hisian left bundle branch block in which permanent distal HB pacing corrects left ventricular delay and produces different QRS morphology at different voltage outputs, as an expression of different selective HB compartments recruitment.CONCLUSION:
This case would strengthen the limited data in the literature about HB longitudinal dissociation.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Estimulação Cardíaca Artificial
/
Eletrocardiografia
Tipo de estudo:
Diagnostic_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2021