Your browser doesn't support javascript.
loading
Micro-Networks for Robust MR-Guided Low Count PET Imaging.
da Costa-Luis, Casper O; Reader, Andrew J.
Afiliação
  • da Costa-Luis CO; Department of Biomedical EngineeringSchool of Biomedical Engineering and Imaging Sciences, St. Thomas' HospitalKing's College LondonLondonSE1 7EHU.K.
  • Reader AJ; Department of Biomedical EngineeringSchool of Biomedical Engineering and Imaging Sciences, St. Thomas' HospitalKing's College LondonLondonSE1 7EHU.K.
IEEE Trans Radiat Plasma Med Sci ; 5(2): 202-212, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33681546
ABSTRACT
Noise suppression is particularly important in low count positron emission tomography (PET) imaging. Post-smoothing (PS) and regularization methods which aim to reduce noise also tend to reduce resolution and introduce bias. Alternatively, anatomical information from another modality such as magnetic resonance (MR) imaging can be used to improve image quality. Convolutional neural networks (CNNs) are particularly well suited to such joint image processing, but usually require large amounts of training data and have mostly been applied outside the field of medical imaging or focus on classification and segmentation, leaving PET image quality improvement relatively understudied. This article proposes the use of a relatively low-complexity CNN (micro-net) as a post-reconstruction MR-guided image processing step to reduce noise and reconstruction artefacts while also improving resolution in low count PET scans. The CNN is designed to be fully 3-D, robust to very limited amounts of training data, and to accept multiple inputs (including competitive denoising methods). Application of the proposed CNN on simulated low (30 M) count data (trained to produce standard (300 M) count reconstructions) results in a 36% lower normalized root mean squared error (NRMSE, calculated over ten realizations against the ground truth) compared to maximum-likelihood expectation maximization (MLEM) used in clinical practice. In contrast, a decrease of only 25% in NRMSE is obtained when an optimized (using knowledge of the ground truth) PS is performed. A 26% NRMSE decrease is obtained with both RM and optimized PS. Similar improvement is also observed for low count real patient datasets. Overfitting to training data is demonstrated to occur as the network size is increased. In an extreme case, a U-net (which produces better predictions for training data) is shown to completely fail on test data due to overfitting to this case of very limited training data. Meanwhile, the resultant images from the proposed CNN (which has low training data requirements) have lower noise, reduced ringing, and partial volume effects, as well as sharper edges and improved resolution compared to conventional MLEM.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article