Your browser doesn't support javascript.
loading
Reliability of 2 Smartphone Applications for Cobb Angle Measurement in Scoliosis.
Ketenci, Ismail Emre; Yanik, Hakan Serhat; Erdogan, Özgür; Adiyeke, Levent; Erdem, Sevki.
Afiliação
  • Ketenci IE; Department of Orthopedics and Traumatology, Haydarpasa Numune Education and Research Hospital, Istanbul, Turkey.
  • Yanik HS; Department of Orthopedics and Traumatology, Haydarpasa Numune Education and Research Hospital, Istanbul, Turkey.
  • Erdogan Ö; Department of Orthopedics and Traumatology, Haydarpasa Numune Education and Research Hospital, Istanbul, Turkey.
  • Adiyeke L; Department of Orthopedics and Traumatology, Haydarpasa Numune Education and Research Hospital, Istanbul, Turkey.
  • Erdem S; Department of Orthopedics and Traumatology, Haydarpasa Numune Education and Research Hospital, Istanbul, Turkey.
Clin Orthop Surg ; 13(1): 67-70, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33747380
ABSTRACT

BACKGROUND:

As mobile technology has evolved, smartphone applications have been used for radiographic angle measurements in daily clinical practice. This study aimed to assess the reliability of 2 smartphone applications (iPinPoint and Cobbmeter) in measuring scoliosis Cobb angles compared with picture archiving and communication system (PACS) tools.

METHODS:

Anteroposterior whole spinal digital radiographs of 50 patients were retrospectively analyzed. Four observers measured Cobb angles of predetermined major structural curves using the tools in the PACS software and 2 smartphone applications. The inter- and intraobserver reliabilty were measured using intraclass correlation coefficients (ICC).

RESULTS:

Very good interobserver agreement was seen with PACS, iPinPoint, and Cobbmeter measurements (ICC, 0.991, 0.980, and 0.991, respectively). Intraobserver reliability of the 4 observers was also very good for all techniques (ICC > 0.9 for all observers).

CONCLUSIONS:

Both smartphone applications were reliable in measuring scoliosis Cobb angles, with reference to PACS tools. They may be useful when digital or manual mesurement tools are not available.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escoliose / Aplicativos Móveis / Smartphone Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escoliose / Aplicativos Móveis / Smartphone Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article