Your browser doesn't support javascript.
loading
Incremental value of three-dimensional transesophageal echocardiography over the two-dimensional technique in the assessment of a partially detached MitraClip.
Meers, Jacob B; Nanda, Navin C; Elmarzouky, Zeyad M; Dulal, Subash; Vardas, Panos N; Ahmed, Mustafa I.
Afiliação
  • Meers JB; Division of Cardiothoracic Anesthesiology, Department of Anesthesiology and Perioperative Medicine, University of Alabama at Birmingham School of Medicine, Birmingham, AL, USA.
  • Nanda NC; Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham School of Medicine, Birmingham, Alabama, USA.
  • Elmarzouky ZM; Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham School of Medicine, Birmingham, Alabama, USA.
  • Dulal S; Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham School of Medicine, Birmingham, Alabama, USA.
  • Vardas PN; Division of Cardiothoracic Surgery, Department of Surgery, University of Alabama at Birmingham School of Medicine, Birmingham, AL, USA.
  • Ahmed MI; Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham School of Medicine, Birmingham, Alabama, USA.
Echocardiography ; 38(4): 693-696, 2021 04.
Article em En | MEDLINE | ID: mdl-33749908
We describe an elderly male patient with two MitraClip devices, one fixed and the other detached, in whom live/real-time three-dimensional echocardiography (3DTEE) provided incremental value and additional information compared to two-dimensional transesophageal echocardiography (2DTEE). 3DTEE offered the ability to comprehensively assess the mitral valve (MV) utilizing full volume and multiplanar reconstruction (MPR) modes. 3DTEE proved useful in assessing the position of the properly attached and the partially detached MitraClip, including assessment of orifice size and degree of mitral regurgitation (MR). In addition, trapping of MV chordae by both clips was noted in the 3DTEE image dataset and confirmed at the time of surgery. Chordal trapping was not detected by 2DTEE. 3DTEE proved useful in more accurately estimating the severity of residual MR with the MitraClips in place since the regurgitant jet vena contracta (VC) could be viewed en face and VC area measured by planimetry in the correct imaging plane as compared to limited linear images from 2DTEE.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ecocardiografia Tridimensional / Insuficiência da Valva Mitral Limite: Aged / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ecocardiografia Tridimensional / Insuficiência da Valva Mitral Limite: Aged / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article