Your browser doesn't support javascript.
loading
Stepwise achievement of high convection volume in post-dilution hemodiafiltration: A prospective observational study.
Kim, Do Hyoung; Lee, Young-Ki; Park, Hayne Cho; Kim, Juhee; Yun, Kyu Sang; Cho, AJin; Noh, Jung-Woo; Kim, Hyunsuk; Kim, Seok-Hyung; Yoon, Jong-Woo.
Afiliação
  • Kim DH; Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
  • Lee YK; Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
  • Park HC; Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
  • Kim J; Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
  • Yun KS; Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
  • Cho A; Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
  • Noh JW; Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
  • Kim H; Department of Internal Medicine, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Korea.
  • Kim SH; Department of Internal Medicine, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Korea.
  • Yoon JW; Department of Internal Medicine, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Korea.
Semin Dial ; 34(5): 368-374, 2021 09.
Article em En | MEDLINE | ID: mdl-33774852
ABSTRACT
High-volume online hemodiafiltration (HDF) has been reported to reduce the patient's mortality. However, achieving a high convection volume is challenging. In this prospective study, we investigated the feasibility of achieving high-volume HDF with ≥21 L substitution volume via modification of blood flow rate (BFR), needle size, and dialysis membrane. In 30 patients undergoing hemodialysis, we followed a stepwise protocol and gradually increased the BFR (280→300→330 ml/min; steps 1, 2, and 3) and needle size (16→15 G; step 4). After changing dialyzer surface area (1.8 m2 →2.5 m2 ), the BFR and needle size were similarly increased stepwise (steps 5, 6, 7, and 8). The mean substitution volume was 18.7 ± 2.2 L at step 1 and it significantly increased to 25.1 ± 2.6 L by step 8. A substitution volume of 21 L was achieved by 13.3% of patients in step 1 and by 96.7% after step 8. The substitution volume was higher for the dialyzer with a large surface area and for the larger needle (15 G). Between steps 1 and 8, the Kt/V and ß2 microglobulin reduction ratios also improved significantly. High-volume HDF is feasible through a stepwise increase in the BFR, needle size, and surface area of the dialysis membrane.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hemodiafiltração Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Hemodiafiltração Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article