Your browser doesn't support javascript.
loading
Assessment of ventricular flow dynamics by 4D-flow MRI in patients following surgical repair of d-transposition of the great arteries.
Callaghan, Fraser M; Burkhardt, Barbara; Valsangiacomo Buechel, Emanuela R; Kellenberger, Christian J; Geiger, Julia.
Afiliação
  • Callaghan FM; University of Zurich, Zurich, Switzerland. fraser.callaghan@kispi.uzh.ch.
  • Burkhardt B; Center for MR-Research, University Children's Hospital, Steinwiesstrasse 75, 8032, Zurich, Switzerland. fraser.callaghan@kispi.uzh.ch.
  • Valsangiacomo Buechel ER; Children's Research Center, University Children's Hospital, Zurich, Switzerland. fraser.callaghan@kispi.uzh.ch.
  • Kellenberger CJ; Children's Research Center, University Children's Hospital, Zurich, Switzerland.
  • Geiger J; Division of Pediatric Cardiology, University Children's Hospital, Zurich, Switzerland.
Eur Radiol ; 31(10): 7231-7241, 2021 Oct.
Article em En | MEDLINE | ID: mdl-33783570
ABSTRACT

OBJECTIVES:

To use 4D-flow MRI to describe systemic and non-systemic ventricular flow organisation and energy loss in patients with repaired d-transposition of the great arteries (d-TGA) and normal subjects.

METHODS:

Pathline tracking of ventricular volumes was performed using 4D-flow MRI data from a 1.5-T GE Discovery MR450 scanner. D-TGA patients following arterial switch (n = 17, mean age 14 ± 5 years) and atrial switch (n = 15, 35 ± 6 years) procedures were examined and compared with subjects with normal cardiac anatomy and ventricular function (n = 12, 12 ± 3 years). Pathlines were classified by their passage through the ventricles as direct flow, retained inflow, delayed ejection flow, and residual volume and visually and quantitatively assessed. Additionally, viscous energy losses (ELv) were calculated.

RESULTS:

In normal subjects, the ventricular flow paths were well ordered following similar trajectories through the ventricles with very little mixing of flow components. The flow paths in all atrial and some arterial switch patients were more irregular with high mixing. Direct flow and delayed ejection flow were decreased in atrial switch patients' systemic ventricles with a corresponding increase in residual volume compared with normal subjects (p = 0.003 and p < 0.001 respectively) and arterial switch patients (p < 0.0001 and p < 0.001 respectively). In non-systemic ventricles, arterial switch patients had increased direct flow and decreased delayed ejection fractions compared to normal (p = 0.007 and p < 0.001 respectively) and atrial switch patients (p = 0.01 and p < 0.001 respectively). Regions of high levels of mixing of ventricular flow components showed elevated ELv.

CONCLUSIONS:

4D-flow MRI pathline tracking reveals disordered ventricular flow patterns and associated ELv in d-TGA patients. KEY POINTS • 4D-flow MRI can be used to assess intraventricular flow dynamics in d-TGA patients. • d-TGA arterial switch patients mostly show intraventricular flow dynamics representative of normal subjects, while atrial switch patients show increased flow disorder and different proportions of intraventricular flow volumes. • Flow disruption and disorder increase viscous energy losses.