Your browser doesn't support javascript.
loading
A thermoluminescent method for the evaluation of the 131I effective half-life in the thyroid when treating Graves' disease.
Meftah, Sabrine; Kraiem, Tarek.
Afiliação
  • Meftah S; Laboratory of Biophysics and Medical Technologies of Tunis, 9 Zouhair Essafi Street, 1006, Tunis, Tunisia. sabrine.meftah1@gmail.com.
  • Kraiem T; University of Tunis Elmanar, Farhat Hached University Campus Tunis, B.P. No. 94-ROMMANA, 1068, Tunis, Tunisia. sabrine.meftah1@gmail.com.
Radiat Environ Biophys ; 60(2): 289-298, 2021 05.
Article em En | MEDLINE | ID: mdl-33797646
ABSTRACT
When planning treatment for Graves' disease with 131I, the effective half-life (Teff) should be estimated individually as it depends on biological characteristics such as iodine uptake and excretion, which differ from an individual to another (Berg et al. 1996). All the methods to quantify Teff described in the literature are quite complex and are difficult to be used in clinical routine. With the aim of optimizing this process, a simplified method is proposed here to evaluate Teff of 131I during treatment of Graves' disease. The present study suggests improving the method of determining Teff based on thermoluminescence dosimetry. This involves implementing a new method and includes reduction of TLD (Thermoluminescent Dosimeter) measurements. The proposed method was validated on patients with Graves' disease. The radiation dose delivered to the patients was determined using the MIRD (Medical Internal Radiation Dosimetry) formalism. The relative difference between Teff obtained based on seven measurement intervals at [0-24 h, 24-48 h, 48-72 h, 72-96 h, 96-120 h, 120-144 h, 144-168 h] and based on three measurement intervals at [0-24 h, 72-96 h, 144-168 h] and [0-24 h, 120-144 h, 144-168 h] was 1.9% and 3.81%, respectively. Comparison of doses obtained based on a general Teff and on a personalized Teff gave a statistically significant difference with a correlation coefficient R2of 0.44. The Teff obtained from just three measurements was found to be sufficiently accurate and easily applicable. The results obtained demonstrate the need to determine and use personalized Teff values instead of using a fixed value of 7 days.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dosimetria Termoluminescente / Antitireóideos / Glândula Tireoide / Doença de Graves / Radioisótopos do Iodo Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dosimetria Termoluminescente / Antitireóideos / Glândula Tireoide / Doença de Graves / Radioisótopos do Iodo Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article