Your browser doesn't support javascript.
loading
Prediction of 10-2 Visual Field Loss Using Optical Coherence Tomography and 24-2 Visual Field Data.
Sullivan-Mee, Michael; Hedayat, Mahdi; Charry, Nicole; Katiyar, Suchitra; Kee, Helen; Kimura, Bryan; Pensyl, Denise.
Afiliação
  • Sullivan-Mee M; Raymond G. Murphy VA Medical Center.
  • Hedayat M; Eye Associates of New Mexico, Albuquerque, NM.
  • Charry N; Raymond G. Murphy VA Medical Center.
  • Katiyar S; Raymond G. Murphy VA Medical Center.
  • Kee H; Raymond G. Murphy VA Medical Center.
  • Kimura B; Raymond G. Murphy VA Medical Center.
  • Pensyl D; Raymond G. Murphy VA Medical Center.
J Glaucoma ; 30(6): e292-e299, 2021 06 01.
Article em En | MEDLINE | ID: mdl-33813565
PRECIS: Using standard glaucoma structural and functional tests, clinicians accurately predicted the presence/absence of 10-2 glaucomatous visual field (VF) loss in 90% of the eyes in this study. PURPOSE: To investigate how well clinicians with variable experience can predict the presence and location of 10-2 VF loss using structural and functional data that are routinely obtained for glaucoma assessment. METHODS: Within a test set of 416 eyes (210 subjects) who were diagnosed glaucoma suspect or primary open-angle glaucoma (with most eyes having mild disease), 6 clinicians were asked to predict the presence and hemispheric location of 10-2 VF loss using 24-2 VF and spectral-domain optical coherence tomography structural data. Prediction accuracies were calculated for each clinician and compared using the weighted κ-statistic. Receiver operating characteristic analyses were used to evaluate models for predicting 10-2 VF loss. RESULTS: Among the 6 clinicians, mean (range) accuracy, false negatives, and false positives for predicting presence/absence of 10-2 VF loss were 90% (87% to 92%), 4.7% (2.4% to 7.0%), and 5.4% (1.7% to 7.5%) respectively. The mean (range) weighted κ-statistic was 0.75 (0.64 to 0.83), suggesting good or very good inter-rater agreement between examiners. Mean accuracy for correctly predicting hemispheric location was 73% (range, 65% to 82%) with the most common error occurring in eyes with both superior and inferior 10-2 VF defects in which one hemisphere was correctly identified but the other missed. CONCLUSIONS: In this study, the presence/absence of 10-2 glaucomatous VF loss was highly predictable using standard functional and structural clinical metrics. These findings suggest that 10-2 VF testing is not needed to reliably recognize and confirm central VF involvement in most eyes with glaucoma. Whether error related to identifying second hemisphere involvement in 10-2 VF loss is important requires further study.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Campos Visuais / Glaucoma de Ângulo Aberto Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Campos Visuais / Glaucoma de Ângulo Aberto Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article