Your browser doesn't support javascript.
loading
Development of hydrophilic magnetic molecularly imprinted polymers for the dispersive solid-phase extraction of sulfonamides from animal-derived samples before HPLC detection.
Zhao, Xiaolei; Lü, Lei; Zhu, Mengzhen; Liu, Huilin; He, Jinxing; Zheng, Fuping.
Afiliação
  • Zhao X; School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, P.R. China.
  • Lü L; School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, P.R. China.
  • Zhu M; School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, P.R. China.
  • Liu H; School of Light Industry, Beijing Technology and Business University, Beijing, P.R. China.
  • He J; School of Food Science and Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, P.R. China.
  • Zheng F; State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, P.R. China.
J Sep Sci ; 44(12): 2399-2407, 2021 Jun.
Article em En | MEDLINE | ID: mdl-33856741
ABSTRACT
Highly hydrophilic magnetic molecularly imprinted polymers were prepared through a surface imprinting technique for dispersive solid-phase extraction coupled with high-performance liquid chromatography to detect trace levels of ten sulfonamides in animal-derived samples. The obtained imprinted polymers were characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis, and adsorption experiments, which exhibited excellent specific adsorption for template sulfamethazine in aqueous solution. Moreover, the adsorption process could be completed within 25 min. Under the optimum conditions, the method exhibits good linear performance in the range of 5-to 10 mg/L, limits of detection ranging from 0.57 to 1.50 µg/L, and good recoveries of 85.09-110.93% in the spiked samples (chicken, cow milk, and goat milk). The proposed detection method not only avoids the use of organic solvents but also simplifies the pretreatment procedure via excellent magnetic properties. Furthermore, the method shows great potential for the rapid detection of drug residues.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sulfonamidas / Extração em Fase Sólida / Polímeros Molecularmente Impressos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sulfonamidas / Extração em Fase Sólida / Polímeros Molecularmente Impressos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article