Your browser doesn't support javascript.
loading
Electrochemical sensor based on multi-walled carbon nanotubes for imidacloprid determination.
Bruzaca, Evellin E S; de Oliveira, Raissa C; Duarte, Mateus S S; Sousa, Camila P; Morais, Simone; Correia, Adriana N; de Lima-Neto, Pedro.
Afiliação
  • Bruzaca EES; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Campus do Pici, 60440-900, Fortaleza, CE, Brazil. adriana@ufc.br.
  • de Oliveira RC; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Campus do Pici, 60440-900, Fortaleza, CE, Brazil. adriana@ufc.br.
  • Duarte MSS; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Campus do Pici, 60440-900, Fortaleza, CE, Brazil. adriana@ufc.br.
  • Sousa CP; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Campus do Pici, 60440-900, Fortaleza, CE, Brazil. adriana@ufc.br.
  • Morais S; REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, R. Dr António Bernardino de Almeida 431, 4200-072, Porto, Portugal.
  • Correia AN; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Campus do Pici, 60440-900, Fortaleza, CE, Brazil. adriana@ufc.br.
  • de Lima-Neto P; Departamento de Química Analítica e Físico-Química, Centro de Ciências, Universidade Federal do Ceará, Campus do Pici, 60440-900, Fortaleza, CE, Brazil. adriana@ufc.br.
Anal Methods ; 13(18): 2124-2136, 2021 05 13.
Article em En | MEDLINE | ID: mdl-33876058
ABSTRACT
A simple and robust sensor (fMWCNT-Nafion®0.5%/GCE) for determination of imidacloprid (IMI), a widely used neonicotinoid, was developed using a glassy carbon electrode (GCE) modified with functionalized multi-walled carbon nanotubes (fMWCNT) and Nafion®. The obtained data suggest that IMI reduction is an irreversible process, due to the reduction of the nitro group to hydroxylamine derivatives, with the participation of two protons and four electrons, and a charge transfer coefficient of 0.141. The optimized square-wave voltammetric conditions were McIlvaine buffer at pH 6.0, 0.5% of Nafion® in the fMWCNT suspension, -0.6 V and 180 s as accumulation potential and time, respectively. A linearity in the range of 2.00 × 10-7 to 1.77 × 10-6 mol L-1 IMI, with the values of limit of detection and limit of quantification were equal to 3.74 × 10-8 mol L-1 and 1.25 × 10-7 mol L-1, respectively. Repeatability and reproducibility displayed relative standard deviations lower than 5%. Recovery tests performed in tap water, melon, and shrimp yielded mean values of 94 ± 6%, 97 ± 10% and 93 ± 10%, respectively. Moreover, several inorganic and organic compounds did not significantly interfere (0.6 to 4.5%) on the IMI signal, proving the selectivity and applicability of the developed sensor for IMI detection in complex samples.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono Idioma: En Ano de publicação: 2021 Tipo de documento: Article