Your browser doesn't support javascript.
loading
Early Clinical and Patient-Reported Outcomes of a New Hybrid Mesh for Incisional Hernia Repair.
Rios-Diaz, Arturo J; Hitchner, Michaela; Christopher, Adrienne N; Broach, Robyn; Cunning, Jessica R; Fischer, John P.
Afiliação
  • Rios-Diaz AJ; Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Surgery. Thomas Jefferson University, Philadelphia, Pennsylvania.
  • Hitchner M; Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania; Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
  • Christopher AN; Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Surgery. Thomas Jefferson University, Philadelphia, Pennsylvania.
  • Broach R; Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania.
  • Cunning JR; Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania.
  • Fischer JP; Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania. Electronic address: john.fischer2@pennmedicine.upenn.edu.
J Surg Res ; 265: 49-59, 2021 09.
Article em En | MEDLINE | ID: mdl-33878576
ABSTRACT

INTRODUCTION:

Consensus on the safety and efficacy of various types of mesh in reconstructing the abdomen has yet to be reached. Hybrid mesh products have been designed to address the need for a cost-effective mesh leveraging the tensile strength of a synthetic mesh while minimizing the prosthetic footprint within the abdominal wall through resorbable materials. In this study we evaluate early clinical outcomes and health related quality of life (HR-QOL) of a new Hybrid mesh, SynecorTM, for Ventral Hernia Repair (VHR).

METHODS:

Adult (>18 y old) patients undergoing VHR with SynecorTM mesh by a single surgeon between 2017-2019 with ≥1-y follow-up were identified. We analyzed a composite of postoperative outcomes as well as the incidence of hernia recurrence, readmissions, mortality, and HR-QOL.

RESULTS:

Thirty-five patients were included in our analysis with a median follow up of 2.1 y. The median age and BMI were 54.1 y and 33.2 kg/m2, respectively. The rate of surgical site occurrences was 37.1%, with only one patient (2.9%) requiring surgical intervention. No patients developed a hernia recurrence. Overall HR-QOL improved significantly (preoperative mean 2.5 [SD 0.7] versus postoperative 3.4 [0.4]; P< 0.01), particularly in regards to pain, functional status, self-esteem and body image (all P < 0.05).

CONCLUSIONS:

Abdominal reinforcement with SynecorTM mesh at the time of VHR results in promising early recurrence rates, an acceptable safety risk profile, and an improvement in overall HR-QOL.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Telas Cirúrgicas / Herniorrafia / Hérnia Ventral Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged País como assunto: America do norte Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Telas Cirúrgicas / Herniorrafia / Hérnia Ventral Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged País como assunto: America do norte Idioma: En Ano de publicação: 2021 Tipo de documento: Article