Your browser doesn't support javascript.
loading
Surface-Enhanced Raman Scattering-Based Dual-Flow Lateral Flow Assay Sensor for the Ultrasensitive Detection of the Thyroid-Stimulating Hormone.
Kim, Kyeongnyeon; Han, Do Kyoung; Choi, Namhyun; Kim, Soo Hyeon; Joung, Younju; Kim, Kihyun; Ho, Ngoc Thanh; Joo, Sang-Woo; Choo, Jaebum.
Afiliação
  • Kim K; Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
  • Han DK; Division of Materials Analysis and Research, Korea Basic Science Institute, Daejeon 34133, South Korea.
  • Choi N; Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
  • Kim SH; Division of Materials Analysis and Research, Korea Basic Science Institute, Daejeon 34133, South Korea.
  • Joung Y; Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
  • Kim K; Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
  • Ho NT; Department of Chemistry, Soongsil University, Seoul 06978, South Korea.
  • Joo SW; Department of Chemistry, Soongsil University, Seoul 06978, South Korea.
  • Choo J; Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
Anal Chem ; 93(17): 6673-6681, 2021 05 04.
Article em En | MEDLINE | ID: mdl-33878867
ABSTRACT
The surface-enhanced Raman scattering (SERS)-based lateral flow assay (LFA) strip has been considered a high-sensitivity sensor that can overcome the low sensitivity and the difficulty of quantitative analysis problems inherent in the colorimetric LFA sensor. In the SERS-based LFA strip reported so far, a liquid sample flows through the nitrocellulose membrane in a single pathway. In some cases, however, this single-flow approach still has a limitation in detection sensitivity. This study developed a conceptually new SERS-based dual-flow LFA sensor to improve the detection sensitivity in a single-flow LFA sensor. First, a 25 nm Raman reporter-labeled gold nanoparticle (AuNP) solution flowed through one way, and a 45 nm AuNP solution continuously flowed through another path. This sequential flow of two different AuNP solutions enables forming additional bright hot spots between 25 and 45 nm AuNPs in the test line, and the SERS signal is strongly enhanced. Using this SERS-based dual-flow LFA sensor, it was possible to detect thyroid-stimulating hormone less than 0.5 µIU/mL that cannot be measured with a SERS-based single-flow LFA sensor.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article