Your browser doesn't support javascript.
loading
Within-session reproducibility of forced oscillometry.
Wollmer, Per; Tufvesson, Ellen; Wennersten, André; Malmqvist, Ulf; Engström, Gunnar; Olsson, Henric K; Zaigham, Suneela; Frantz, Sophia; Nihlén, Ulf.
Afiliação
  • Wollmer P; Clinical Physiology and Nuclear Medicine Unit, Department of Translational Medicine, Lund University, Lund, Sweden.
  • Tufvesson E; Respiratory Medicine and Allergology, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
  • Wennersten A; Family Medicine and Community Medicine, Department of Clinical Sciences Malmö, Lund University, Lund, Sweden.
  • Malmqvist U; Division of Clinical Chemistry and Pharmacology, Department of Laboratory Medicine, Lund University, Lund, Sweden.
  • Engström G; Cardiovascular Research - Epidemiology, Department of Clinical Sciences Malmö, Lund University, Lund, Sweden.
  • Olsson HK; Translational Science and Experimental Medicine, Research and Early Development, Respiratory & Immunology, BioPharmaceuticals R&D, AstraZeneca, Gothenburg, Sweden.
  • Zaigham S; Cardiovascular Research - Epidemiology, Department of Clinical Sciences Malmö, Lund University, Lund, Sweden.
  • Frantz S; Clinical Physiology and Nuclear Medicine Unit, Department of Translational Medicine, Lund University, Lund, Sweden.
  • Nihlén U; Respiratory Medicine and Allergology, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.
Clin Physiol Funct Imaging ; 41(5): 401-407, 2021 Sep.
Article em En | MEDLINE | ID: mdl-33914403
ABSTRACT

BACKGROUND:

The forced oscillation technique (FOT) provides detailed information about the mechanics of the respiratory system, while requiring minimal co-operation by the patient. FOT may be abnormal in subjects with normal spirometry and appears to be more closely related to airway symptoms. It is, therefore, attractive in epidemiological studies, where a large number of different examinations are made in each subjects in a short period of time. Current technical standards recommend the mean of three consecutive measurements to be used, but there is limited information regarding within-session variability of FOT measurements.

OBJECTIVE:

The purpose of this study was to examine the within-session variability in FOT measurements in a large, population-based sample.

METHODS:

We performed three consecutive FOT measurements in 700 subjects using the impulse oscillometry system. The first measurement was compared to the mean of three measurements for resistance at 5 and 20 Hz (R5 and R20, respectively), R5-R20, reactance at 5 Hz (X5) and resonant frequency (fres ).

RESULTS:

The differences between the first and the mean of three measurements (median, interquartile range) were minimal, for example 0.002, -0.008 to 0.014 kPa L-1  s for R5 and -0.001, -0.008 to 0.005 kPa L-1  s for X5. Findings were numerically similar for men and women as well as for subjects with and without airflow obstruction at spirometry.

CONCLUSIONS:

We conclude that, whereas in clinical situations, three FOT measurements are to be preferred, a single measurement may suffice in epidemiological studies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resistência das Vias Respiratórias / Doença Pulmonar Obstrutiva Crônica Tipo de estudo: Guideline Limite: Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Resistência das Vias Respiratórias / Doença Pulmonar Obstrutiva Crônica Tipo de estudo: Guideline Limite: Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article